Rev. 00 04/19
58
Operation
OptiCenter OC06
The user does not have to be logged in to operate the OptiCenter
with its basic functions.
– More about the login procedure See chapter "Login" on page 36.
After logging in, the following functions are available to the user:
–
Configuration*
–
Diagnostic
–
Settings
3.
Select operating mode:
Coating with powder recovery
Coating without powder recovery (spray to waste
container)
Cleaning operation mode
4.
Set all other plant components to the correct operating mode (for
more information, see the relevant operating instructions)
– If some plant components are not yet ready for operation, a
message will be displayed.
Coating with powder recovery (spray)
1.
2.
3.
If a US sieve** has already been configured, insert and close the
OptiSpeeder cover with the appropriate mesh size
– If there are several mesh sizes, the corresponding menu
appears for selecting the mesh size used