5
2 • TECHNICAL DATA
90027360rev00
TABLE 2: GENERAL DATA GAS OVENS
Model
Supply
voltage
Frequency
Imput
Motor
Oil-proof
connection cable
( * )
Gas power
w/boiler
Gas power
w/o boiler
Gas
connection
5 x GN 1/1
6 x GN 1/1
AC 230 V
50 Hz
0,25 kW
1 x 0,2 kW
3 x 1 mm
2
-
8,5 kW
1 x R 1/2”
7 x GN 1/1
8 x GN 1/1
AC 230 V
50 Hz
0,5 kW
1 x 0,37 kW
3 x 1 mm
2
15 kW
12 kW
1 x R 1/2”
10 x GN 1/1
AC 230 V
50 Hz
1 kW
1 x 0,55 kW
3 x 1 mm
2
28 kW
18 kW
1 x R 1/2”
7 x GN 2/1
AC 230 V
50 Hz
1 kW
1 x 0,55 kW
3 x 1 mm
2
30 kW
20 kW
1 x R 1/2”
10 x GN 2/1
AC 230 V
50 Hz
1 kW
1 x 0,55 kW
3 x 1 mm
2
40 kW
27 kW
1 x R 1/2”
20 x GN 1/1
AC 230 V
50 Hz
1,8 kW
2 x 0,55 kW
3 x 1,5 mm
2
48 kW
36 kW
1 x R 3/4”
20 x GN 2/1
AC 230 V
50 Hz
1,8 kW
2 x 0,55 kW
3 x 1,5 mm
2
80 kW
54 kW
1 x R 3/4”
Caution:
The residual current device to be installed between the mains and the appliance
must be sized for a leakage of 1 mA x kW of power installed.
( * ) Flexible cable underneath sheath resistant to oil with designation 60245-IEC-57