 CAUTION

Welding!

Damage to the valve actuator or valve body.

Observe welding standards.

 CAUTION

Wrong solvent cement

Valve body will be damaged.

Only use solvent cement suitable for the valve body.

NOTICE

The solvent cement is not included in the scope of deliv-
ery.

Only use suitable solvent cement!

1. Push the union nut 

1

 over the piping 

4

. Connect the insert

5

 with the piping 

4

 by cementing / welding.

1

2

2. Unscrew union nut 

1

 from valve body 

2

.

3

3. Reinsert O-ring 

3

 if necessary.

4. Screw the union nut 

1

 to the valve body 

2

 again.

5. Connect the other side of the valve body 

2

 to the piping 

4

,

too.

5

1 4

2

3

10 Electrical connection

 DANGER

Risk of electric shock

Risk of injury or death (if operating
voltage is higher than safe extra low
voltage).

Electric shock can cause severe burns
and fatal injury.

Work on electrical connections only by
qualified trained personnel.

Disconnect the cable from the power
supply before making the electrical
connection.

Connect the protective earth con-
ductor.

 CAUTION

AC voltage

Solenoid valve will be destroyed by wrong plug.

Solenoid valves used with AC voltage may only be oper-
ated with a plug with a built-in rectifier.

1

2

3

4

1. Insert the cable through the locking screw 

1

, the pressure

ring 

2

, the seal 

3

 and the housing of the plug 

4

.

1

2

Supply voltage

Item

Name

1

Supply voltage

2

Supply voltage

Protective earth conductor (PE)

2. Connect the cable to the relevant terminals on the ter-

minal block.

3. Push the terminal block into the housing of the plug (acc.

to DIN EN 175301-803, previously DIN 43650) until it aud-
ibly clicks in position.

4. Ensure that the cable is not caught.

5. Tighten the locking screw on the plug.

10 Electrical connection

Summary of Contents for 225 DN 10

Page 1: ...GEM 225 Electrically operated solenoid valve Operating instructions EN further information webcode GW 225...

Page 2: ...rights including copyrights or industrial property rights are expressly reserved Keep the document for future reference GEM Gebr M ller Apparatebau GmbH Co KG 18 02 2021 www gemu group com 2 24 GEM 2...

Page 3: ...iping 12 9 1 Installation with solvent cement sockets 12 9 2 Installation with solvent cement spigots 12 9 3 Installation with threaded sockets 12 9 4 Installation with union ends 12 10 Electrical con...

Page 4: ...um The medium that flows through the GEM product 1 4 Warning notes Wherever possible warning notes are organised according to the following scheme SIGNAL WORD Type and source of the danger Possible sy...

Page 5: ...on and operating personnel 5 Ensure that the contents of the document have been fully understood by the responsible personnel 6 Define the areas of responsibility 7 Observe the safety data sheets 8 Ob...

Page 6: ...chamber through the pilot seat than can flow in through the control aperture The differential pressure produced lifts the diaphragm thus opening the main valve seat 2 4 Correct use DANGER Danger of e...

Page 7: ...Spigot inch 30 5 Valve body material Code PVC U grey 1 6 Seal material Code FPM 4 EPDM 14 7 Control function Code Normally closed NC 1 8 Voltage Code 24 V 24 120 V 120 230 V 230 9 Frequency Code DC D...

Page 8: ...tandards used EN 55011 1991 150 kHz to 30 MHz EN 55014 1993 148 5 kHz to 30 MHz 6 4 Mechanical data Protection class IP 65 Weight DN 10 DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 0 85 0 9 0 9 2 8 2 8 3 6 3 6...

Page 9: ...8 W Permissible voltage toler ance 10 to VDE 0580 Duty cycle Continuous duty Wiring note Special wiring on request When using electronic switches and additional wiring carefully design out any potenti...

Page 10: ...8 88 110 110 Dimensions in inch 7 2 Body dimensions 7 2 1 Solvent cement spigot code 0 30 H1 H L C d Connection Code1 DN 20 DN 25 DN 32 DN 40 DN 50 C 19 22 26 31 39 d 0 25 32 40 50 63 30 26 7 33 4 H 5...

Page 11: ...1 1 4 H 63 63 H1 30 30 D 43 53 LA 108 108 LB 146 152 Dimensions in inch 7 3 Mounting dimensions G E DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 E 40 40 44 5 44 5 44 5 44 5 G M5 M5 M8 M8 M8 M8 10 32 UNF 10 32...

Page 12: ...e body Only install the solenoid valve in aligned pipes in order to avoid stresses in the valve body Do not exceed the permissible operating pressure Do not exceed the permissible temperature of the w...

Page 13: ...afe extra low voltage Electric shock can cause severe burns and fatal injury Work on electrical connections only by qualified trained personnel Disconnect the cable from the power supply before making...

Page 14: ...TICE Operating pressure too high The valve cannot be opened electromagnetically if the operating pressure is too high CAUTION Foreign matter Damage to the valves If the plant is new and after repairs...

Page 15: ...e parts Damage to the GEM product Manufacturer liability and guarantee will be void Use only genuine parts from GEM CAUTION Hot plant components Risk of burns Only work on plant that has cooled down N...

Page 16: ...with the valves fully open The plant operator is responsible for selecting the clean ing material and performing the procedure Clean the product with a damp cloth Do not clean the product with a high...

Page 17: ...nnected Check connection of plug and correct if necessary Operating pressure too high Check operating pressure reduce if ne cessary PTFE bush leaking Replace solenoid valve Armature blocked Replace so...

Page 18: ...and gas diffu sion from penetrated media 2 Dispose of all parts in accordance with the disposal regu lations environmental protection laws 17 Returns Legal regulations for the protection of the envir...

Page 19: ...iled in accordance with part B of Annex VII The manufacturer or his authorised representative undertake to transmit in response to a reasoned request by the national authorities relevant information o...

Page 20: ...land Industrie Service GmbH Number 0035 Certificate no 01 202 926 Q 02 0036 Conformity assessment procedure Module H Technical standard used EN 1983 AD 2000 Note for products with a nominal size DN 25...

Page 21: ...www gemu group com 21 24 GEM 225...

Page 22: ...www gemu group com 22 24 GEM 225...

Page 23: ...www gemu group com 23 24 GEM 225...

Page 24: ...EM Gebr M ller Apparatebau GmbH Co KG Fritz M ller Stra e 6 8 74653 Ingelfingen Criesbach Ger many Phone 49 0 7940 1230 info gemue de www gemu group com Subject to alteration 02 2021 88593469 88593469...

Reviews: