7
www.geiger.de
EN
EN
13. What to do if…
Problem
Solution
Motor does not run.
• Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow the
cause of the voltage break down to be
tested by a specialist electrician.
Instead of in the downwards direction,
motor runs upwards.
• The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
• Motor in the end position.
Run motor in the opposite direction.
Readjust the end positions, if necessary.
After running several times,
the motor breaks down and
no longer responds.
• The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
14. Maintenance
The drive is maintenance-free.
15. Technical data
Technical data GJ56.. E11 with electronic end stop
GJ5620
Voltage
230 V~/50 Hz
Current
0,85 A
Cos Phi (cos
j
)
> 0,95
Inrush current (factor)
x 1,2
Power
190 W
Torque
2 x 10 Nm
Speed
26 1/min
Protection class
IP 54
Limit switch range
200 rotations
Operating mode
S2 4 min.
Length
356,7 mm
Diameter
55 mm
Weight
approx. 2,20 kg
Storage temperature/
Humidity
T = -15°C .. +70°C / dry and non-condensing place
Subject to technical modifications. Please find information to the ambient
temperature range of our GEIGER motors under www.geiger.de
D E
V
geprüfte
Sicherheit
16. Notes on waste disposal
Recycling of packaging materials
In the interest of environmental protection, please contact your local government’s recycling or
solid waste management department to learn more about the services it provides.
Waste disposal of electric and electronic equipment
Electrical and electronic equipment must be collected and disposed of separately in accordance
with EU regulations.