background image

6

4.2  Safe Operation

Comply  with  the  requirements  of  accident  prevention  regulation  “Processing  of  Coating

Materials” (e.g. in Germany VBG 23).

All persons using the

ABAC

 Motor Blower must have read and understood this Operating

Manual, particularly the section entitled “Safety Notes”.

The

ABAC

 SG 2500 Motor Blower is not of flame-proof design. Take care to ensure that

there are no ignition sources in the vicinity, such as naked flames, sparks, glowing wires,

hot  surfaces,  lighted  cigarettes  etc.  The  distance  between  spray  jet  exit  and  a  possible

source of ignition (even the Blower itself) must be at least 5 m (fire and explosion hazard

from ignitable spray mist).

It  must  not  be used  in  works  locations  subject  to  the provisions of  explosion  prevention

regulation, or on premises and in areas where there is a risk of fire.

Use only paints and solvents with a flash point of 21

°

C/70

°

F or higher without additional

heating (see details on paint tin).

When  working  in  confined  spaces,  these  must  be  properly  ventilated  using  effective

technical ventilation systems.

The sprayed paint emerges from the nozzle at high pressure. Never direct the spray jet at

people  or  animals.  If  the  skin  is  injured  by  paint,  lacquer  or  solvent  there  is  a  risk  of

infection. Seek medical treatment immediately and tell the doctor which paint, lacquer or

solvent was used.

Poisonous  fumes  may  be  given  off  during  spraying  (see  paint  tin  for  details).  Use  a

breathing mask as directed by paint manufacturer’s instructions. Keep children and other

people away from the working area.

The

ABAC

 SG 2500 Motor Blower is not splash-proof. It must not be used out of doors,

when it is raining or splashed or washed with water or immersed in liquid.

Keep  the

ABAC

  SG  2500  Motor  Blower  in  a  safe  place  that  is  inaccessible  to  children

and  unauthorized  personnel.  Make  sure  that  no  unauthorized  personnel  (particularly

children) can put the

ABAC

 SG 2500 Motor Blower into operation.

Store your Motor Blower in a dry ventilated room.

For  safety  reasons  you  should  only  use

ABAC

  original  accessories  and

ABAC

  original

spare parts.

Summary of Contents for ABAC SG 2500

Page 1: ...Geheit GmbH Benzstraße 2 D 72636 Frickenhausen Germany Phone 49 0 7022 78969021 Fax 49 0 7022 78969029 www shop geheit de Motor Blower SG 2500 Operating Manual ...

Page 2: ...adas aplicadas Приложени хармонизирани стандарти Εφαρμοσμένα εναρμονισμένα πρότυπα Norme armonizate aplicate Zastosowane normy zharmonizowane Применимые гармонизированные нормы Pielietotie harmonizētie standarti Kohaldatud harmoniseeritud normid Taikyti darnieji standartai Použité harmonizované normy Použité harmonizované normy Uporabljeni harmonizirani standardi Alkalmazott harmonizált szabványok...

Page 3: ... Care Maintenance and Repair 9 8 1 Replacing Intake Filter 9 9 Faults Possible Causes and Remedies 10 10 Operating Instructions 11 11 Spare Parts 11 2019 by Geheit GmbH Printed in Germany All rights reserved but particularly the right of duplication distribution and translation No part of this publication may be reproduced in any form printed photocopying microfilming or by any other method withou...

Page 4: ...1 0000 230 V Always observe and comply with all processing instructions and safety notes provided by material manufacturers as well the prescriptions of this operating manual In any case only paints and solvents with a flash point above 21 C 70 F may be used for spraying The ABAC Motor Blower SG 2500 is designed to be operated in connection with PN 1 PN 1A PN 2 PN 2A and PN 5 ABAC Spray Guns which...

Page 5: ...the motor two separate intake filters are installed Figure 1 NOTE Enter the serial number marked on the rating plate of your Blower in figure 1 Keep your operating manual and its attached CE declaration of conformity in a safe place GEHEIT GmbH D 72636 Frickenhausen Made in Germany Typ SG 2500 Fab No AC 100 115 V 1 N 50 60 Hz 1500 W 16 0 A 21000 min Volumenstrom max 2 7 m3 min Betriebsdruck max 0 ...

Page 6: ...C 100 V 1 N 50 60 Hz AC 115 V 1 N 50 60 Hz AC 230 V 1 N 50 60 Hz o Insulation Protection Class 3 o Power 1500 W o Power consumption approx 16 A 100 V approx 16 A 115 V approx 7 A 230 V o Speed 21 000 min 1 max o Protection Type IP 20 o Quantity of Air adjustable max 2 7 m min o Operating Pressure approx 0 35 bar max o Length 230 mm o Width 240 mm o Height 435 mm o Weight 9 7 kg ...

Page 7: ...tely remedied by an authorized person The SG 2500 Motor Blower is intended for use with our own ABAC low pressure spray guns which operate in the low pressure range up to 0 45 bar You must also follow the instructions given in the relevant operating manuals for these ABAC low pressure spray guns It must not be used for any other purpose The manufacturer or supplier is not responsible and will not ...

Page 8: ... tin When working in confined spaces these must be properly ventilated using effective technical ventilation systems The sprayed paint emerges from the nozzle at high pressure Never direct the spray jet at people or animals If the skin is injured by paint lacquer or solvent there is a risk of infection Seek medical treatment immediately and tell the doctor which paint lacquer or solvent was used P...

Page 9: ...uthorized specialists or by us Addresses of authorized firms can be obtained from us or from your dealer upon request When spraying take care not to spray in the direction of your Motor Blower Dispose of your cleaning and spraying material wastes according to the instructions given by the relevant lacquer paint and solvent manufacturers Provide the replacement of blower filters in time and on regu...

Page 10: ...nector clockwise in the blower opening 6 2 Switching on and Adjusting the Blower Plug the Blower into the mains and press the green button of the ON OFF switch with the thumb Use the rotary knob of the speed governor to adjust air quantity and pressure continuously and match air quantity and pressure generated by motor blower operation to the paint being used The Blower can thus be adapted to mate...

Page 11: ...otor does not require any customer servicing to be carried out 8 1 Replacing Intake Filter Attention Switch off the Motor Blower disconnect from mains and wait until motor is stationary before opening intake vents Please take notice that the closure is a screw joint To unlock the device cover you may need the screwdriver Always replace both intake filters when they are dirty Do not attempt to clea...

Page 12: ...air Rotary knob incorrectly set Reset rotary knob such that required air quantity is delivered Motor Blower is not running No mains voltage Check mains connection Motor protection has tripped Wait a while and press the green button on the device switch Carbon brushes worn Repair only by approved workshop ABAC Motor Blower defective Repair only by approved workshop ABAC Air quantity cannot be regul...

Page 13: ... read and observed by all employees 11 Spare Parts For safety reasons you should only use ABAC original accessories and ABAC original spare parts Spare parts are available from your ABAC specialist dealer or directly from our company For speedy and efficient ordering of spare parts we require the following details Equipment type serial number Designation of the part identification number Quantity ...