DISSIPATION CURVES

TABLE OF TERMINALS AND CONDUCTORS

Curves of rated current according to room temperature.

N.B.: Curves for the GTS 120 refer to the device complete with standard running.

10/15/

6,4x9

Eye/fork/ 6mm

2

20A

M3

Faston type conn*     0.6Nm Max

25A

6,4x9

Eye/fork/ 6mm

2

(GTS)

M3

Faston type conn*     0.6Nm Max

40A

6,3x9

Eye/fork/ 2.5mm

2

25A

(

GTS-T)

M3

tip

0.6Nm Max

50/60A

6,3x9

Eye/fork/ 2.5mm

2

M3

tip

0.6Nm Max

75-90A

6,3x9

Eye/fork/ 2.5mm

2

M3

tip

0.6Nm Max

120A

6,3x9

Eye/fork/ 2.5mm

2

M3

tip

0.6Nm Max

6,4x9

Eye/fork/                       6mm

2

M3

conn tipo Faston* 

0.4-0.6 Nm

6,4x9

Eye/fork 6mm

2

M3

0.4-0.6 Nm

12x12

Eye/fork 16mm

2

M5

1.5-2.2 Nm

16x18

Eye/fork 50mm

2

M6

3.5-6 Nm

16x18

Eye/fork 50mm

2

M6

3.5-6 Nm

16x18

Eye/fork 50mm

2

M6

3.5-6 Nm

9x12

6mm

2

M5

1.3-1.8 Nm

9x12

6mm

2

M5

1.3-1.8 Nm

11,5x12

16mm

2

M5

1.5-2.2 Nm

14x16

50mm

2

M5

1.8-2.5Nm

14x16

50mm

2

M5

1.8-2.5 Nm

14x16

50mm

2

M5

1.8-2.5 Nm

Contact Type of pre-

Max section. **

Size

area      isolated terminal

conductor

(WxD)

tightening

screw type 

torque

Contact  Type of pre-             Max section. **
area 

isolated terminal      conductor

(WxD)

tightening

screw type

torque

Contact

Max section. **

area

conductor

(WxD)

tightening

screw type

torque

CONTROL TERMINAL

POWER TERMINAL

GROUND TERMINAL

(*) Female faston (for insertion, remove the M3 screw by making the nut re-enter the seat in the holder)
(**)The max. sections specified refer to unipolar copper wires isolated in PVC.. 
•    Note: For the ground terminal, you have to use an eye wire terminal. 

(WxD) =  Width x depth

40

35

30

25

20

15

10

I (A)

0

40

80

T(C

°

)

25

15

30

25

10

I (A)

70

60

50

40

30

20

10

0

40

80

T(C

°

)

15

20

30

40

50

60

40

50

GTS-T

GTS 15 - 25

GTS 40 - 50 - 60

GTS 75 - 90 - 120

Summary of Contents for GTS-T 10 Series

Page 1: ...2V Max reverse voltage 36Vdc GTS T10 T20 T25 TRIAC version Control voltage 5 32Vdc Activation voltage 4 2Vdc Deactivation voltage 2Vdc GTS 15 120A versione SCR Control voltage 6 32Vdc Activation volta...

Page 2: ...temperature da 0 a 80 C according to dissipation curves Max relative humidity 50 at 40 C Max installation altitude 2000m asl Pollution level 3 Storage temperature 20 85 C Installation notes Use the h...

Page 3: ...27 mm 108 mm 100 mm 14 mm 18 mm 50 mm max Depth 142 mm Weight GTS 75 90 1300 g Weight GTS 120 1700 g Depth 142 mm Weight 900 g Depth 142 mm Weight 540 g Depth 107 mm Weight 320 g The ON LED is red dur...

Page 4: ...ON OFF Control GTS 60A 480 Vac AC1 50 60 Hz ON AL Load Line 6 32Vcc ON OFF Control GTS 60A 480 Vac AC1 50 60 Hz ON AL R R R R R R Load Line AC1 50 60 Hz GTS 60A 480 Vac ON OFF Control 6 32Vcc AL ON Lo...

Page 5: ...mm2 M6 3 5 6 Nm 9x12 6mm2 M5 1 3 1 8 Nm 9x12 6mm2 M5 1 3 1 8 Nm 11 5x12 16mm2 M5 1 5 2 2 Nm 14x16 50mm2 M5 1 8 2 5Nm 14x16 50mm2 M5 1 8 2 5 Nm 14x16 50mm2 M5 1 8 2 5 Nm Contact Type of pre Max section...

Page 6: ...d voltage 230 230Vac GTS T 230 Version with TRIAC Rated current 15 15Aac 25Aac 40Aac 60Aac 90Aac 25 40 60 90 120Aac 120 Rated voltage 230 230Vac Model GTS GTS Version with double SCR Please contact GE...

Page 7: ...s and heat sources respect the installation distances between one device and another to allow for dissipation of generated heat to keep air in movement we advise you to install a fan near the GTS grou...

Reviews: