background image

CONNECTION EXAMPLES

Ground

Phase R

Phase T

Phase S

AC1 50/60 Hz

GT 25A/480 Vac

4..20mA

0..20mA

0..5V

0..10V

g Alarm Adj

c Reset Alarm

f Input selection
e Max Adj
d Min Adj

Load

L2

Line

480 V

i

230 V

Line

Line

h

L1

AL

PWR

ON

Analog

Supply

8

Out

6

7

5

24 Vac

+10 Vdc

Input

Slave

30 Vdc/ac

4

3

2

1

Out

Alarm

Master

AC1 50/60 Hz

GT 25A/480 Vac

4..20mA

0..20mA

0..5V

0..10V

g Alarm Adj

c Reset Alarm

f Input selection
e Max Adj
d Min Adj

Load

L2

Line

480 V

i

230 V

Line

Line

h

L1

AL

PWR

ON

Analog

Supply

8

Out

6

7

5

24 Vac

+10 Vdc

Input

Slave

30 Vdc/ac

4

3

2

1

Out

Alarm

Master

Potentiometer

Relay output - Alarm
(Solid state relay)

Digital output

0-20mA
4-20mA

0-10Vdc

0-5Vdc

Star or delta three-phase connection without neutral, with control of two phases.

Controller

24Vac 1,5VA

Fuse

Fuse

*

Connections regarding the
load interrupted option (see
paragraph “Interrupted load
alarm)
Note: connect or i
according to the load
tension.

*

*

*

*

*

Three-phase connection

Star connection

4

5

6

7

8

+10 Vdc

24 Vac

Supply

Out

Input

Analog

1

2

3

Out

30 Vdc/ac

Alarm

Master

Slave

ON

PWR

AL

4..20mA

d Min Adj

AC1 50/60 Hz

GT 25A/480 Vac

0..20mA

c Reset Alarm

L1

h

i

L2

0..5V

0..10V

Load

Line

480 V

f Input selection

g Alarm Adj

e Max Adj

Line

Line

230 V

4

5

6

7

8

+10 Vdc

24 Vac

Supply

Out

Input

Analog

1

2

3

Out

30 Vdc/ac

Alarm

Master

Slave

ON

PWR

AL

4..20mA

d Min Adj

AC1 50/60 Hz

GT 25A/480 Vac

0..20mA

c Reset Alarm

L1

h

i

L2

0..5V

0..10V

Load

Line

480 V

f Input selection

g Alarm Adj

e Max Adj

Line

Line

230 V

4

5

6

7

8

+10 Vdc

24 Vac

Supply

Out

Input

Analog

1

2

3

Out

30 Vdc/ac

Alarm

Master

Slave

ON

PWR

AL

4..20mA

d Min Adj

AC1 50/60 Hz

GT 25A/480 Vac

0..20mA

c Reset Alarm

L1

h

i

L2

0..5V

0..10V

Load

Line

480 V

f Input selection

g Alarm Adj

e Max Adj

Line

Line

230 V

Potentiometer

Relay output - Alarm

(Solid state relay)

Digital output

0-20mA
4-20mA

0-10Vdc

0-5Vdc

Controller

24Vac 1,5VA

Phase R

Phase S

Phase T

Ground

Load

Fuse

Fuse

Fuse

*

*

*

*

*

*

*

*

Connections regarding the
load interrupted option (see
paragraph “Interrupted load
alarm)
Note: connect or i
according to the load
tension.

Star or delta three-phase connection without neutral, with control of three phases.

Summary of Contents for GT 120A

Page 1: ...ermediate values The units offer optional accessoires for panel mounting fuses and fuseholders current transformer isolation transformers Use the rel with an opportune heatsink see section accessories...

Page 2: ...h junction ambient 12 K W Solid State Relay Dissipated Power Calculation Singol phase static relay Pds 1 4 IRMS W IRMS singol phase load current Heatsink thermal resistance Calculation Rth 90 C T amb...

Page 3: ...ifferent cycle times 100msec and 40msec respectively V V Example of input at 20 2V IN 0 10V or 4mA IN 0 20mA V Voltage across load Example of input at 50 5V IN 0 10V or 10mA IN 0 20mA V Voltage across...

Page 4: ...ge for potentiometer power supply 10V 24 Vac 50 60 Hz power terminal The solid state power unit Gt is supplied factory calibrated for 0 5V 0 10V 0 20mA 4 20mA 10Kohm potentiometer Minimum and maximum...

Page 5: ...ther 1 10 of a turn 1 notch on the scale In this way the alarm limit is set below 10 of the rated load current N B the partial load break alarm function operates with power partialization exceeding 15...

Page 6: ...PLES L2 h L1 i Master AL PWR Line 230 V GT 25A 480 Vac e Max Adj d Min Adj c Reset Alarm f Input selection g Alarm Adj Line 30 Vdc ac ON 2 Out Alarm 1 Slave 3 Line 480 V 0 10V 0 20mA 4 20mA 0 5V AC1 5...

Page 7: ...6 7 8 10 Vdc 24 Vac Supply Out Input Analog 1 2 3 Out 30 Vdc ac Alarm Master Slave ON PWR AL 4 20mA d Min Adj AC1 50 60 Hz GT 25A 480 Vac 0 20mA c Reset Alarm L1 h i L2 0 5V 0 10V Load Line 480 V f In...

Page 8: ...th neutral Controller Relay output Alarm solid state relay Digital output 0 20mA 4 20mA 0 10Vdc 0 5Vdc Three phase connection triangle or star without neutral with control of two phases using one GT i...

Page 9: ...es thermostats current transformers and isolation transformers To choose accessories see the section Solid state relays Accessories Fuse Fuse Fuse TABLE OF TERMINALS AND CONDUCTORS 25 40A 6 3x9 Eye fo...

Page 10: ...y from dust humidity corrosive gases and heat sources The connection cable must be shorter than 3 meters if the current transformer is used Maintenance Check the correct operation of the cooling fans...