ADV200 SP • Quick start up guide - Specification and installation
10.8 Braking resistor (optional)
Recommended resistors for use with internal braking unit (except ADV200
SP-DC models):
Sizes
List and technical data of standard external resistors
Resistor type
Code
Max Overload
energy,
1”- duty-cycle
10%
E
br
(kJ)
Max Overload
energy,
30”- duty-cycle
25%
E
br
(kJ)
Braking resistor
nominal power
P
nbr
(W)
Resistance
value
R
br
(
Ω
)
Enclo-
sure
1015
RF 220 T 100R
S8T0CE
1.5
11
220
100
IP44
1022
RF 220 T 100R
S8T0CE
1.5
11
220
100
IP44
1030
RF 300 DT 100R
S8T0CB
2.5
19
300
100
IP44
1040
RF 300 DT 100R
S8T0CB
2.5
19
300
100
IP44
1055
RFPD 750 DT 100R
S8SY4
7.5
38
750
100
IP44
2075
RFPD 750 DT 68R
S8T0CD
7.5
38
750
68
IP44
2110
RFPD 900 DT 68R
S8SY5
9
48
900
68
IP44
2150
RFPD 1100 DT 40R
S8SY6
11
58
1100
40
IP44
3185
RFPR 1900 D 28R
S8SZ5
19
75
1500
28
IP44
3220
BRT4K0-15R4
S8T00G
40
150
4000
15.4
IP20
3300
BRT4K0-15R4
S8T00G
40
150
4000
15.4
IP20
4370
BRT4K0-11R6
S8T00H
40
150
4000
11.6
IP20
4450
BRT4K0-11R6
S8T00H
40
150
4000
11.6
IP20
4550
BRT8K0-7R7
S8T00I
40
150
8000
7.7
IP20
5750
BRT8K0-7R7
S8T00I
40
150
8000
7.7
IP20
≥ 5900 and
ADV200 SP-...-DC
External braking unit (BUy series, optional)
Resistor type
Code
Dimensions (Wx H x d) - mm
Weights (kg)
RF 220 T 100R
S8T0CE
300 x 27 x 36
0,5
RF 300 DT 100R
S8T0CB
260 x 47 x 108
1,4
RFPD 750 DT 100R
S8SY4
200 x 70 x 106
1,7
RFPD 750 DT 68R
S8T0CD
200 x 70 x 106
1,7
RFPD 900 DT 68R
S8SY5
260 x 70 x 106
2,2
RFPD 1100 DT 40R
S8SY6
320 x 70 x 106
2,7
RFPR 1900 D 28R
S8SZ5
365 x 75 x 100
4,2
BRT4K0-15R4
S8T00G
625 x 100 x 250
7,0
BRT4K0-11R6
S8T00H
625 x 100 x 250
7,0
BRT8K0-7R7
S8T00I
625 x 160 x 250
11,5
Braking resistors may be subject to unexpected overloads due to faults.
Resistors MUST be protected using thermal cutouts. These devices must not interrupt the circuit in which the
resistor is inserted but their auxiliary contact must cut off the power supply to the power section of the drive. If
the resistor requires a protection contact, this must be used together with that of the thermal cutout.
A la suite de pannes, les résistances de freinage peuvent être sujettes à des surcharges imprévues. La protec-
tion des résistances au moyen de dispositifs de protection thermique est absolument capitale. Ces dispositifs ne
doivent pas interrompre le circuit qui abrite la résistance, mais leur contact auxiliaire doit couper l’alimentation du
côté puissance du drive. Si la résistance prévoit un contact de protection, ce dernier doit être utilisé conjointe-
ment à celui du dispositif de protection thermique.