Gefen GTB-HD4K2K-848-BLK User Manual Download Page 59

page | 47

Commands

A

dv

anc

ed Oper

ation

#recall_preset

Loads the specified routing preset.

Syntax

#recall_preset

Parameters

None

Example

#recall_preset 2

RECALLED THE ROUTING STATE OF PRESET 2

Related Commands

#save_preset

#set_preset_name

#show_preset_name

Summary of Contents for GTB-HD4K2K-848-BLK

Page 1: ...GTB HD4K2K 848 BLK User Manual 8x8 Matrix for HDMI Release A5 60Hz 4 2 0...

Page 2: ...the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the unit 11 Only use attachments accessor...

Page 3: ...cular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Coppe...

Page 4: ...Time Fax 818 772 9120 Email support gefen com Web http www gefen com Mailing Address Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 Product Registration Register your product her...

Page 5: ...vice environment This feature cannot be disabled When powering the 4K Ultra HD 8x8 Matrix for HDMI or if the EDID mode is changed the 4K Ultra HD 8x8 Matrix for HDMI will undergo a momentary initializ...

Page 6: ...with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the follow...

Page 7: ...ntegration of sources and displays Supports LPCM 7 1 Dolby TrueHD Dolby Digital Plus and DTS HD Master Audio Supports the use of DVI sources and DVI displays with HDMI to DVI adapters not included RS...

Page 8: ...tems listed below If any of these items are not present in the box when you first open it immediately contact your dealer or Gefen 1 x 4K Ultra HD 8x8 Matrix for HDMI 1 x IR Remote 1 x 24V DC Power Su...

Page 9: ...This page left intentionally blank...

Page 10: ...ix 17 Fast Switching Technology 18 Fast Slow Switching Modes 19 IR Control 21 Setting the IR Channel 21 Using the IR Remote 23 Using the IR Extender 25 EDID Management 26 External EDID Management 26 3...

Page 11: ...ettings 122 Configuration Telnet Login Settings 123 Configuration UDP Connection Settings 124 Configuration Web Login Settings 125 Configuration System Configuration 126 4 Appendix Mounting Instructio...

Page 12: ...This page left intentionally blank...

Page 13: ...4K Ultra HD 8x8 Matrix for HDMI 1 Getting Started...

Page 14: ...etting Started Power Lock Power In In Out Out Lock Menu RS 232 IR Ext USB IP Control 24V DC IR 4K Ultra HD 8x8 Matrix for HDMI Power Lock Power In In Out Out Lock Menu RS 232 IR Ext USB IP Control 24V...

Page 15: ...tle Introduction Getting Started Out H Out G Out F Out E Out D Out C Out B Out A In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 Out H Out G Out F Out E Out D Out C Out B Out A In 1 In 2 In 3 In 4 In 5 In 6 I...

Page 16: ...omation device 5 IR Ext Connect an IR extender Gefen part no EXT RMT EXTIRN to this port 6 USB This mini USB port is used for upgrading the firmware 7 IP Control Connect a CAT 5e cable or better from...

Page 17: ...indicator This LED will be activated momentarily each time an input or output button is pressed 2 Input buttons Press these buttons to select an input 1 8 3 Output buttons Press these buttons to selec...

Page 18: ...ormation 2 Primary battery slot shown without battery Holds the battery for operating the remote Use only 3V CR2032 type batteries Make sure that the positive side of the battery is facing up 3 Altern...

Page 19: ...cover Setting the IR Remote Channel In order for the included IR remote control to communicate with the 4K Ultra HD 8x8 Matrix for HDMI the IR remote control must be set to the same channel as the ma...

Page 20: ...ble from the IP Control port on the matrix to a Local Area Network LAN RS 232 4 Connect an RS 232 cable from the RS 232 port on the matrix to the RS 232 connector on the automation controller IR 5 Con...

Page 21: ...HD4K2K 848 BLK 4K Ultra HD 8x8 Matrix for HDMI RS 232 Controller EXT RMT EXTIRN IR Extender LAN for IP Control DB 9 CABLE HDMI CABLE CAT 5 CABLE GTB HD4K2K 848 BLK IR EXTENDER 8x 4K Ultra HD Source Un...

Page 22: ...This page left intentionally blank...

Page 23: ...4K Ultra HD 8x8 Matrix for HDMI 2 Basic Operation...

Page 24: ...on the following screen is displayed After a few moments the status screen is displayed The status screen is shown below Consecutively pressing the Menu button on the front panel will cycle through o...

Page 25: ...uted to Outputs A B C and D Continuing Input 4 is routed to Output E Input 6 is routed to Output F Input 8 is routed to Output G and finally Input 1 is routed to Output H If all inputs are routed to t...

Page 26: ...gain to cycle through the routing state for each output Consecutively pressing the Out button will cycle through each output from left to right starting with Output A Fundamentals Power Lock Power In...

Page 27: ...pressing the In button will decrement the input source value by a factor of 1 within a range of 1 8 For example if Input 7 was originally routed to Output G then pressing the In button will route Inpu...

Page 28: ...ttons to change the source 7 Press the Menu button to accept the new routing state and return to the status screen Power Lock Power In In Out Out Lock Menu IR OUT ABCDEFGH IN 12345678 Basic Operation...

Page 29: ...el 2 The Lock LED will glow bright orange to indicate that the front panel buttons on the matrix have been locked If any buttons other than the Lock button are pressed while the 4K Ultra HD 8x8 Matrix...

Page 30: ...x to be disconnected re connected and or powered ON or OFF without these events from interfering with the behavior of other sources and displays Fast Mode Setting the 4K Ultra HD 8x8 Matrix for HDMI t...

Page 31: ...mode screen is displayed The first row IN represents each HDMI input on the matrix The bottom row MODE represents the current switching mode of the HDMI input By default all inputs are set to fast F m...

Page 32: ...ect a different input press the Out or Out buttons 7 Press the Menu button to accept the routing changes and return to the switching mode screen 8 Press the Menu button a second time to return to the...

Page 33: ...ol unit Follow the procedure outlined below to set the IR channel on the matrix 1 From the status screen simultaneously press the In In and Out buttons 2 The current IR address will be displayed along...

Page 34: ...Therefore the DIP switch 1 on the IR Remote Control must be set to the ON position and DIP switch 2 must be set to the OFF position 5 Press the Menu button to return to accept the changes and return t...

Page 35: ...nel of the matrix 2 Select Output C by pressing button C on the IR Remote Control The letter C will appear in the upper right hand corner of the LCD display 3 Select Input 4 by pressing button 4 on th...

Page 36: ...bers on the far right hand of the LCD display will disappear and the new routing state will be displayed in the LCD display Input 4 is now routed to Output C Power Lock Power In In Out Out Lock Menu R...

Page 37: ...onnected to the IR Ext port on the matrix The sensor on the IR extender behaves exactly like the sensor on the top panel of the matrix Always point the IR remote control unit at the IR sensor IR Contr...

Page 38: ...ices This involves reading EDID data from more than one device Management of the EDID data is important to maintain compatibility between all devices The following EDID features are copied from Output...

Page 39: ...This page left intentionally blank...

Page 40: ...This page left intentionally blank...

Page 41: ...4K Ultra HD 8x8 Matrix for HDMI 3 Advanced Operation...

Page 42: ...Syner G Software Suite The Gefen Syner G Software Suite is free software that is available from the Gefen Web site 1 Download and install the Gefen Syner G Software Suite Download the application here...

Page 43: ...k 6 Click the Save button at the bottom right corner of the screen 7 Click the Reboot button 8 Click the Web GUI link above the Reboot button to access the built in web interface The following table l...

Page 44: ...dware flow control None DA 15 DE 9 DB 25 DC 37 DD 50 5 6 4 7 3 8 2 9 1 DCD RXD TXD DTR GND DSR RTS CTS R1 DCD RXD TXD DTR GND DSR RTS CTS R1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 RS 232 Controller Matri...

Page 45: ..._edid Sets the type of EDID to use set_http_port Sets the HTTP listening port set_input_name Sets the name of the specified input set_ir Sets the IR channel of the matrix set_output_name Sets the name...

Page 46: ...ame of the specified routing preset show_r Displays the routing state of the matrix show_rsense Displays the Rsense status of the specified output show_telnet_port Displays the Telnet listening port s...

Page 47: ...ables disables the Telnet welcome message during a Telnet session Syntax display_telnet_welcome Parameters param1 Integer 0 1 Value Description 0 Disable welcome message 1 Enable welcome message Examp...

Page 48: ...anced Operation echo Enables disables toggles the RS 232 feedback Syntax echo param1 Parameters param1 Integer 0 1 Value Description 0 Disable feedback 1 Enable feedback Example echo 1 LOCAL ECHO IS O...

Page 49: ...ed Operation fadefault Resets the matrix to factory default settings Outputs are unmasked and all IP and UDP settings are reset to default settings Syntax fadefault Parameters None Example fadefault R...

Page 50: ...p Enables disables HDCP detection on the selected input Syntax hdcp param1 Parameters param1 Integer 0 1 Value Description 0 Disable HDCP 1 Enable HDCP Example hdcp 4 0 INPUT 4 HDCP IS DISABLE Related...

Page 51: ...the list of available RS 232 Telnet commands Help on a specific command can be displayed when using param1 Syntax hdcp param1 Parameters param1 Integer 0 1 Example help sipadd SIPADD PARAM 1 SET THE I...

Page 52: ...is identical to physically disconnecting and reconnecting the cable between the source and the matrix If param1 0 then all inputs will receive the HPD pulse Syntax hpd_pulse param1 Parameters param1 I...

Page 53: ...ig The ipconfig command displays the current TCP settings Syntax ipconfig Parameters None Example ipconfig IP Configuration is IP 10 5 64 247 NETMASK 255 255 0 0 GATEWAY 10 5 64 1 Related Commands res...

Page 54: ...ID by disabling the automatic loading of the downstream EDID when the matrix is powered Syntax lock_edid param1 Parameters param1 Integer 0 1 Value Description 0 Disable 1 Enable Example lock_edid 1 M...

Page 55: ...ks or unlocks the matrix When the matrix is locked all functions are disabled including the front panel RS 232 and Telnet Syntax lock_matrix param1 Parameters param1 Integer 0 1 Value Description 0 Un...

Page 56: ...s If param1 0 then all outputs are masked Use the unmask command to disable output masking Syntax mask param1 Parameters param1 Integer Character 0 A H Examples mask A F G OUTPUTS A F G ARE MASKED ma...

Page 57: ...page 45 Commands Advanced Operation power Powers ON or OFF the matrix Syntax power param1 Parameters param1 Integer 0 1 Value Description 0 Power OFF 1 Power ON Example power 1 Related Commands reboot...

Page 58: ...ng this command is the equivalent of cycling power on the matrix The matrix must be rebooted after changing any of the IP settings Syntax reboot Parameters None Example reboot MATRIX WILL REBOOT SHORT...

Page 59: ...ed Operation recall_preset Loads the specified routing preset Syntax recall_preset Parameters None Example recall_preset 2 RECALLED THE ROUTING STATE OF PRESET 2 Related Commands save_preset set_prese...

Page 60: ...Operation resetip Resets the IP configuration to factory default settings The matrix must be rebooted after executing this command Syntax resetip Parameters None Example resetip Related Commands fade...

Page 61: ...set Saves the current routing state to the specified preset Syntax save_preset param1 Parameters param1 Integer 1 8 Example save_preset 2 CURRENT ROUTING STATE IS SAVED TO PRESET 2 Related Commands re...

Page 62: ...nk_name Assigns a name to the specified bank Syntax set_bank_name param1 param2 Parameters param1 Integer 1 8 param2 String Example set_bank_name 5 SonyXBR SonyXBR NAME IS ASSIGNED TO BANK 5 Related C...

Page 63: ...Assigns a name to the matrix The description cannot exceed 30 characters in length Syntax set_device_descr param1 Parameters param1 String Example set_device_descr 8x8Matrix DEVICE DESCRIPTION NAME IS...

Page 64: ...rameters param1 String param1 Description default Use default EDID dynamic Use dynamic EDID bank Use EDID bank output Use EDID on Output param2 Integer 0 1 8 param1 Description 0 Default Dynamic 1 8 B...

Page 65: ...is important when using Dynamic EDID Examples set_edid dynamic 0 input 4 COPY DYNAMIC EDID TO INPUT4 In this example Input 4 is set to Dynamic EDID If the following routing command is issued then the...

Page 66: ...ust be rebooted after executing this command The default port setting is 80 Use the show_http_port command to display the current HTTP listening port Syntax set_http_port param1 Parameters param1 Inte...

Page 67: ...ssigns a name to the specified input Syntax set_input_name param1 param2 Parameters param1 Integer 1 8 param2 String Example set_input_name 3 Blu ray Blu ray NAME IS ASSIGNED TO INPUT 3 Related Comman...

Page 68: ...also be set under the Configuration tab within the Web interface See Configuration System Configuration for more information Syntax set_ir param1 Parameters param1 Integer 0 3 param1 Description 0 IR...

Page 69: ...15 characters Names longer than 15 characters will be truncated To name an output use the set_output_name command Syntax set_output_name param1 param2 Parameters param1 Character A H param2 String Exa...

Page 70: ...preset is limited to 8 characters To display the name of a preset use the show_preset_name command Syntax set_preset_name param1 param2 Parameters param1 Integer 1 8 param2 String Example set_preset_...

Page 71: ...net_pass command sets the Telnet password The password is case sensitive and cannot exceed 8 characters in length The default password is Admin Syntax set_telnet_pass param1 Parameters param1 String E...

Page 72: ...after executing this command The default port setting is 23 Use the show_telnet_port command to display the current Telnet listening port Syntax set_telnet_port param1 Parameters param1 Integer 1 102...

Page 73: ...nd The default port setting is 23 Use the show_telnet_port command to display the current Telnet listening port Syntax set_udp_port param1 Parameters param1 Integer 1 1024 Example set_udp_port 50007 U...

Page 74: ...ied using dot decimal notation The default UDP remote IP address is 192 168 1 255 The matrix must be rebooted after executing this command Syntax set_udp_port param1 Parameters param1 String Example s...

Page 75: ...ult remote UDP listening port is 50008 The matrix must be rebooted after executing this command Syntax set_udp_remote_port param1 Parameters param1 Integer 0 65535 Example set_udp_remote_port 50007 UD...

Page 76: ...assword for the Web GUI The password is case sensitive and cannot exceed 7 characters in length The default password is Admin Syntax set_webui_ad_pass param1 Parameters param1 String Example set_webui...

Page 77: ...set_webui_ad_pass command sets the Operator password for the Web GUI The default password is Admin Syntax set_webui_op_pass param1 Parameters param1 String Example set_webui_op_pass m1ni0n Web UI Ope...

Page 78: ...mal notation The matrix must be rebooted after executing this command The default gateway is 192 168 1 1 Syntax sgateway param1 Parameters param1 String Example sgateway 10 5 64 1 GateWay Address 10 5...

Page 79: ...nced Operation show_bank_name Displays the name for the specified EDID bank Syntax show_bank_name param1 Parameters param1 Integer 1 8 Example show_bank_name 5 THE NAME FOR BANK 5 IS SonyXBR Related C...

Page 80: ...splays the device description Use the set_device_descr command to set the device description Syntax show_device_descr Parameters None Example show_device_descr DEVICE DESCRIPTION NAME IS SET TO 8x8Mat...

Page 81: ...Advanced Operation show_discovery Displays the current state of the discovery feature Syntax show_discovery Parameters None Example show_discovery DISCOVERY PROTOCOL IS ENABLED Related Commands show_...

Page 82: ...page 70 Commands Advanced Operation show_fw Displays the current version of firmware Syntax show_fw Parameters None Example show_fw FIRMWARE VERSION GTB HD4K2K 848 v1 0H Advanced Operation...

Page 83: ...ds Advanced Operation show_gateway Displays the gateway address of the matrix Syntax show_gateway Parameters None Example show_gateway GATEWAY ADDRESS IS 10 5 64 1 Related Commands ipconfig sgateway s...

Page 84: ...ration show_hdcp Displays the HDCP status of the specified input Use the hdcp command to enable or disable HDCP Syntax show_hdcp Parameters None Example show_hdcp 3 INPUT 3 HDCP IS ENABLED Related Com...

Page 85: ...ow_hpd Displays the HPD status of the specified output The name of the output is included in the feedback Syntax show_hpd param1 Parameters param1 Character A H Example show_hpd D HPD OF OUTPUT D OUTP...

Page 86: ...plays the current HTTP listening port of the matrix Use the set_http_port command to set the HTTP listening port Syntax show_http_port Parameters None Example show_http_port HTTP COMMUNICATION PORT IS...

Page 87: ...Displays the name of the specified input To name an input use the set_input_name command Syntax show_input param1 Parameters None Example show_input_name 3 THE NAME FOR INPUT 3 IS Blu ray Related Comm...

Page 88: ...the current gateway address of the matrix Use the sipadd command to set the IP address of the matrix Syntax show_ip Parameters None Example show_ip IP ADDRESS IS 10 5 64 247 Related Commands ipconfig...

Page 89: ...t IR channel of the matrix The IR channel of the matrix must match the IR channel of the IR remote control See Setting the IR Remote Channel page 7 for more information Syntax show_ir Parameters None...

Page 90: ...nds Advanced Operation show_mac_addr The show_mac_addr command displays the MAC address of the matrix Syntax show_mac_addr Parameters None Example show_mac_addr MAC ADDRESS IS 00 1a 07 11 01 76 Advanc...

Page 91: ...mands Advanced Operation show_mask Displays the mask status of the specified output Syntax show_mask param1 Parameters param1 Character A H Example show_mask b OUTPUT B OUTPUT2 IS UNMASKED Related Com...

Page 92: ..._me Enables or disables the show me feature on the matrix Syntax show_me Parameters param1 Integer 1 2 param1 Description 0 Disabled 1 Enabled Example show_me 1 SHOW ME IS ON Related Commands show_dis...

Page 93: ...ow_netmask Displays the current subnet mask address of the matrix Use the snetmask command to set the subnet mask address Syntax show_netmask Parameters None Example show_netmask NETMASK ADDRESS IS 25...

Page 94: ...fied display based on the EDID of the connected sink display device If no display is attached to the specified output then the command will return NO SIGNAL Syntax show_out_colordpt param1 Parameters...

Page 95: ...by the specified display based on the EDID of the connected sink display device If no display is attached to the specified output then the command will return NO SIGNAL Syntax show_out_res param1 Para...

Page 96: ...of the output To name an output use the set_output_name command Syntax show_output_name param1 Parameters param1 Character A H Example show_output_name D THE NAME FOR OUTPUT D IS Samsung Related Comm...

Page 97: ...e for the specified preset To assign a name to a preset use the set_preset_name command Syntax show_preset_name param1 Parameters param1 Integer 1 8 Example show_preset_name 4 THE NAME FOR PRESET 4 IS...

Page 98: ...d Operation show_r Displays the routing status of the specified output Syntax show_r param1 Parameters param1 Character A H Example show_r B OUTPUT B OUTPUT2 IS ROUTED TO INPUT 3 INPUT3 Related Comman...

Page 99: ...vanced Operation show_rsense Displays the Rsense status of the specified output Syntax show_rsense param1 Parameters param1 Character A H Example show_rsense A RSENSE OF OUTPUT A OUTPUT1 IS LOW Relate...

Page 100: ...lays the current Telnet port of the matrix Use the set_telnet_port command to set the Telnet listening port Syntax show_telnet_port Parameters None Example show_telnet_port TELNET COMMUNICATION PORT I...

Page 101: ...ed Operation show_telnet_username Displays the user name for the current Telnet session Syntax show_telnet_username Parameters None Example show_telnet_username User Name For TELNET Is Admin Related C...

Page 102: ...Displays the current local UDP listening port Use the set_udp_port command to set the local UDP listening port Syntax show_udp_port Parameters None Example show_udp_port UDP COMMUNICATION PORT IS 5000...

Page 103: ...te_ip Displays the remote UDP IP address Use the set_udp_remote_ip command to set the remote UDP IP address Syntax show_udp_remote_ip Parameters None Example show_udp_remote_ip REMOTE UDP IP ADDRESS I...

Page 104: ...lays the remote UDP port Use the set_udp_remote_port command to set the remote UDP remote port Syntax show_udp_remote_port Parameters None Example show_udp_remote_ip REMOTE UDP COMMUNICATION PORT IS 5...

Page 105: ...e 93 Commands Advanced Operation show_ver_data Displays the current software and hardware version Syntax show_ver_data Parameters None Example show_ver_data SOFTWARE AND HARDWARE VERSION v3 2B PCB 170...

Page 106: ...booted after executing this command The default IP address is 192 168 1 72 Use the show_ip or ipconfig command to display the current IP address of the matrix Syntax sipadd param1 Parameters param1 St...

Page 107: ...ust be rebooted after executing this command The default net mask is 255 255 255 0 Use the ipconfig or show_netmask command to display the current net mask of the matrix Syntax snetmask param1 Paramet...

Page 108: ...pecified output s Multiple outputs may be specified If param1 0 then all outputs are unmasked Syntax unmask param1 param8 Parameters param1 Integer Character 0 A H Examples unmask e OUTPUT E IS UNMASK...

Page 109: ...ables the discovery feature By default the discovery feature is enabled Syntax use_discovery param1 Parameters param1 Integer 0 1 param1 Description 0 Disabled 1 Enabled Example use_discovery 1 DISCOV...

Page 110: ...default setting is 0 disabled Use the set_telnet_pass command to set the Telnet password Syntax use_telnet_pass param1 Parameters param1 Integer 0 1 param1 Description 0 Disabled 1 Enabled Example use...

Page 111: ...Advanced Operation use_udp_enable Enables or disables UDP access mode Syntax use_udp_enable param1 Parameters param1 Integer 0 1 param1 Description 0 Disabled 1 Enabled Example use_udp_enable 0 UDP A...

Page 112: ...he matrix Masking and locking status of the matrix is also provided Do not precede the m command with the symbol Syntax m Parameters None Example m Out A B C D E F G H In 1 2 3 4 5 6 7 8 ALL OUTPUTS A...

Page 113: ...status of the specified output Do not precede the n command with the symbol If param1 0 then the routing state for all outputs is returned Syntax n param1 Parameters param1 Integer Output 0 A H Exampl...

Page 114: ...d input param1 will be routed to all outputs Up to eight inputs can be specified at a time param2 param9 Syntax r param1 param2 param9 Parameters param1 Integer 1 8 param2 Integer Character 0 A H Exam...

Page 115: ...peration s The s command routes the specified input to all outputs Do not precede this command with the symbol Syntax s param1 Parameters param1 Integer 1 8 Example s 6 INPUT 6 IS SET TO ALL OUTPUTS R...

Page 116: ...the drop down list Options Operator Administrator Administrator login provides unrestricted access to all features and settings Operator login limits access to matrix routing display information and...

Page 117: ...n set of sub tabs Click on the desired tab sub tab to open the desired page Main Routing Output The number of outputs that are available for routing Input The input that is currently routed to the out...

Page 118: ...puts Outputs Check to select the currently active output Input Inputs Click the radio button next to the desired input to be routed Name Inputs Displays the current name of the input This name can be...

Page 119: ...locked settings cannot be changed using the front panel buttons or through the Web GUI When the matrix is locked the button text will read Unlock Matrix and a red bar will appear across the top portio...

Page 120: ...name of the output can be changed using the set_output_name command or through the I O Setup I O Names page 112 page of the Web interface RSENSE Displays the current Rsense state Mask Displays the mas...

Page 121: ...Web Interface Input Displays the state of each input for each of the following Input name Color Depth Color Space HDCP 3D Active Signal Vertical Resolution Horizontal Resolution Progressive Interlaced...

Page 122: ...he drop down list The selected EDID will be copied from the Output or selected EDID Bank to the desired input s and used by the source Options 1 Bank1 8 Bank8 A Output1 H Output8 Feature Audio Formats...

Page 123: ...Setup Preset Names Preset The number of each preset Name Type the desired name of each preset in these fields Save Changes Saves the current changes to the name of the preset s Cancel Restores the pre...

Page 124: ...ed name of each output in these fields Input The number of each input Name Input Type the desired name of each the input in these fields Save Changes Saves the current changes to the name of the outpu...

Page 125: ...of each input can be changed using the set_input_name command or through the I O Setup I O Names page 112 page of the Web interface Pulse Click the Pulse button to cycle the HPD line on the desired i...

Page 126: ...nput Name The name of the input The name of each input can be changed using the set_input_name command or through the I O Setup I O Names page of the Web interface Check All Selects all FST check boxe...

Page 127: ...b interface Check All Places a check mark in all boxes under the Disable column Clear All Clears all check marks from the Disable column Set Click this button to save changes for all input s Cancel Ca...

Page 128: ...DID locked on power cycle message will be displayed in red The local EDID information will now be locked once the matrix is rebooted Click the Unlock EDID button to disable the Lock EDID feature Copy...

Page 129: ...check box to select or deselect the desired input s These check boxes can only be used when the EDID Mode is set to Custom User EDID Modes Select the EDID mode from the drop down list Options Custom...

Page 130: ...wnstream EDID of the sink device connected to Output 1 Custom Last Output Uses the EDID from the last output on the matrix For example this matrix has a total of two outputs If a sink device is connec...

Page 131: ...EDID Bank Names Bank Indicates the EDID bank number Name Type the desired name of the EDID bank in this field Save Changes Saves the current name change to the EDID bank s Cancel Restores the previou...

Page 132: ...wse Click this button to select the EDID file to be uploaded Select Bank Location Click this drop down list to select the bank to where the EDID will be uploaded Options 1 Bank 1 8 Bank 8 Upload Click...

Page 133: ...e to Download Click this box to select the EDID that is to be saved to a file The EDID file will be saved in binary bin format Options 1 Bank 1 8 Bank 8 A OUTPUT1 H OUTPUT8 1 INPUT1 8 INPUT8 Download...

Page 134: ...Saves the current settings for the Change IP Settings After clicking this button the Web interface will display a dialog indicating that the matrix must be rebooted for changes to take effect Set Def...

Page 135: ...x to have the matrix prompt for a password each time a Telnet session is started This box must be checked in order to change the Telnet Login credentials Show Login Message on Connect Click this check...

Page 136: ...Settings Remote UDP IP Address Type the remote UDP IP address in this text box Remote UDP Port Enter the remote UDP port in this text box Enable UDP Access Check this box to enable UDP access If this...

Page 137: ...select the user name The credentials for the selected user name can now be changed Old Password Type the current old password in this field New Password Type the new password in this field Confirm Pa...

Page 138: ...page 126 Web Interface Advanced Operation Configuration System Configuration continued on next page Download Click this button to download the current matrix configuration to a file...

Page 139: ...date Updates the matrix with the selected firmware file Browse Click this button to select the saved configuration file to be loaded into memory Browse Click this button to select the firmware file to...

Page 140: ...This page left intentionally blank...

Page 141: ...page 129 4K Ultra HD 8x8 Matrix for HDMI 4 Appendix...

Page 142: ...enough clearance for insertion and retraction of cables at the HDMI connectors For installation on a drywall surface use a 6 drywall screw It is recommended when installing on a drywall surface that s...

Page 143: ...or extenders from the 4K Ultra HD 8x8 Matrix for HDMI during the update process 5 Click the Configuration tab in the Web interface and click the Browse button under the System Configuration section 6...

Page 144: ...ter is able to connect to the 4K Ultra HD 8x8 Matrix for HDMI a removable disk icon will be displayed under My Computer 5 Extract the firmware file from the ZIP file and drag the bin file to the Remov...

Page 145: ...i stereo Power Indicator 1 x LED bi color red green Lock Indicator 1 x LED orange Display 1 x 2 row 16 character Control Buttons 7 x tact type Operational Maximum Pixel Clock 300 MHz Power Supply 24V...

Page 146: ...0 545 6900 818 772 9100 fax 818 772 9120 www gefen com support gefen com Stretch it Switch it Split it Gefen s got it 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120...