![Gefen EXT-DVI-16416 User Manual Download Page 19](http://html.mh-extra.com/html/gefen/ext-dvi-16416/ext-dvi-16416_user-manual_2205188019.webp)
15
RS-232 / IP CONTROL
RS-232 Interface
Only TXD, RXD, and GND are used.
RS232 Settings
Baud rate .......................................................................................................................19200
Data bits ............................................................................................................................... 8
Parity bits ....................................................................................................................... None
Stop bits ................................................................................................................................1
Flow Control ................................................................................................................... None
IMPORTANT:
When sending RS-232 commands, a carriage return
must be included at the end of the command. A space
must
be
included between the command and the parameter.
DA-15
DE-9
DB-25
DC-37
DD-50
5
6
4
7
3
8
2
9
1
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
R1
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
R1
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9