How to Resolve IR Code Confl icts

In the event that IR commands from other remote controls confl ict with the 
supplied RMT-2IR remote control, changing the remote channel will alleviate 
this issue. The RMT-2IR remote control and the 2x1 DisplayPort KVM both have 
banks of DIP (Dual Inline Package) switches for confi guring the remote channel 
that both units use to communicate. These settings must exactly match each 
other for proper operation. 

The DIP switch bank on the RMT-2IR is located underneath the battery cover. 
DIP switch banks for the 2x1 DisplayPort KVM are located on the underside of 
the unit beneath a black piece of metallic tape. Switches 1 and 2 on the RMT-2IR 
directly correspond to DIP Switches 1 and 2 on the 2x1 DisplayPort KVM. Only 
switches 1 and 2 (of 4 in that bank) are used for IR Code settings.

Remote Channel 1:
Default

1     2

Remote Channel 2:

1     2

Remote Channel 3:

1     2

Remote Channel 4:

1     2

Left: 

Picture of the opened rear battery 

compartment of the RMT-2IR remote showing 
the exposed DIP Switch bank between the 
battery chambers.

2x1 DisplayPort KVM DIP Switch Settings

Remote Channel 1:
Default

Remote Channel 4:

1 2 3 4

1 2 3 4

Remote Channel 3:

1 2 3 4

Remote Channel 2:

1 2 3 4

INFRARED (IR) CODE CHANNEL CONFIGURATION

Summary of Contents for EXT-DPKVM-241

Page 1: ...www gefen com f 2x1 DisplayPort KVM EXT DPKVM 241 User Manual...

Page 2: ...en LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 www gefen com support gefen com Notice Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying doc...

Page 3: ...Connecting And Operating The 2x1 DisplayPort KVM 7 Operating The 2x1 DisplayPort KVM 8 RMT 2IR Remote Control Description 9 RMT 2IR Remote Installation 10 Infrared IR Code Channel Configuration 11 RS...

Page 4: ...ontrol signals are switched for each computer upon selection providing an easy and effective method of accessing two computers from one workstation without the hassle of network Switching can also be...

Page 5: ...EDID is normally required by source host devices to determine the capabilities of the attached peripherals The 2x1 DisplayPort KVM features complete EDID passthrough This means that when EDID is prese...

Page 6: ...pact connector for easier installations Switches up to 2560x1600 maximum resolution Supports RGB and YCbCr color spaces Package Includes 1 DisplayPort KVM Switcher 2 6 foot DisplayPort cable 2 6 foot...

Page 7: ...4 Front Panel Back Panel 2 1 6 3 7 3 8 4 7 9 9 10 5 11 12 12 13 13 PANEL LAYOUT...

Page 8: ...ice The currently selected DisplayPort input source will be output via this port 9 3 5mm Analog Audio Input 1 2 This port will accept audio from a single 3 5mm analog mini jack source Two ports are av...

Page 9: ...USB Type B inputs using the included USB Type A to B cables USB Input 1 will be routed to the connected USB devices when Input 1 is selected and USB Input 2 will be routed to the connected USB device...

Page 10: ...on switching via the front panel selector button please see this page 2 For information on switching via the infrared IR remote control please see page 8 3 For information on switching via RS 232 ser...

Page 11: ...ce All devices connected to the input ports labeled 1 will be selected and output 2 Pressing this button will select Input 2 as the source All devices connected to the input ports labeled 2 will be se...

Page 12: ...into the open battery slot The positive side should be facing up Ensure that both DIP Dual Inline Package switches are in the OFF position Replace the battery cover The remote ships with 2 batteries O...

Page 13: ...DIP switch banks for the 2x1 DisplayPort KVM are located on the underside of the unit beneath a black piece of metallic tape Switches 1 and 2 on the RMT 2IR directly correspond to DIP Switches 1 and 2...

Page 14: ...tested by using any Windows PC with the Hyperterminal program What pins are used for communication with the 2x1 DisplayPort KVM Only pins 2 Receive 3 Transmit and 5 Ground are used for communication...

Page 15: ...user to utilize a contact closure type of remote control such as Gefen product EXT RMT 2 to initiate input switching By default this switch is in the OFF position and will rely on the standard switch...

Page 16: ...or 2 USB 2 0 Type B from computers Output Connector 2 USB 2 0 Type A to keyboard mouse Input Connector 2 3 5mm analog L R audio from computers Output Connector 1 3 5mm analog L R audio to speakers or...

Page 17: ...Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Copper cables are limited to a 30 day warranty and cables...

Page 18: ......

Page 19: ...ma DPKVM 241 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefen com support gefen com Rev A1 Pb This product uses UL listed power supplies...

Reviews: