To clear the UMD
Enter a “space”, and then click “OK”, the character in UMD bar will be cleared.
2) Dynamic UMD:
Choose “TSL” in the drop-down list and click “Settings”.
Dynamic UMD of MIO MVS-4HD is achieved by Ethernet.
Here are a few steps to achieve dynamic UMD:
First, set the TSL port on Network page to be the same as the ones of TSL Tallyman. The default value
is 163. Enter the new port value in the blank area, click “OK”, and then restart the unit. After it goes
back to work, the new TSL port value takes effect.
Second, set the target address for selected channel to receive the data from TSL Tallyman. Please
make sure there is no same target address for the channels, that is, each target address has unique
value for each channel.
Tally Settings
Two kinds of Tally mode are provided. They are Static Tally and Dynamic Tally.
Choose “None” in the drop-down list
The Tally function is disabled and Tally turns gray.
Via GPI-Static Tally
The same as control device,
such as TSL Tallyman
Do restart the unit after
changing port value.