1
2
3
Generator Harness Connector EN07
FE02-9411b
(a)
Turn the ignition switch to "OFF" position.
(b)
Disconnect generator harness connector EN07.
(c)
Measure voltage between generator harness connector
EN07 terminal No.2 and a reliable ground.
Standard Voltage: 11-14 V
(d)
Connect generator harness connector EN07.
Is the voltage specified value?
No
Yes
Step 7
Replace the generator. Refer to
Step 8
Are Instrument cluster, electric windows, air-conditioning system working properly?
No
Relay IG1 does not provide IG1 power. Check
the IG1 relay.
Yes
Step 9
The circuit between EN07 terminal No.2 and instrument cluster fuse IF25 is open. Check and repair the faulty
part.
Next
Step 10
Diagnostic completed.
2.11.7.7 Charging Indicator Always Off
Step 1
Connect the ignition switch, and keep the engine off, is battery charging indicator on?
No
Intermittent Fault. Refer to
Yes
Step 2
Disconnect generator harness connector EN07, is battery charging indicator on?
No
Yes
Step 3
Check the generator regulator power supply circuit.
Refer to
Step 4.
Is the voltage specified value?
2-568
Starting / Charging System JL4G18-D
Engine
EC718/EC718RV EC715/EC715RV 10/2009
Summary of Contents for EC715 2009
Page 4: ......
Page 330: ...Next Step 10 End 2 248 Fuel System JL4G18 D Engine EC718 EC718RV EC715 EC715RV 10 2009 ...
Page 1164: ......
Page 2008: ......