Swivel Arm Hoist
GEDA STAR 200 STANDARD / GEDA STAR 250 COMFORT
14.4 Every 3000 operating hours
Change the grease on the gear of the cable drum gear motor.
-
Grease amount = approx. 600 g on the GEDA-STAR 250 COMFORT
-
Grease amount = approx. 1600 g on the GEDA-STAR 200 STANDARD
-
Recommendation: DIVINOL, ARAL-Lub FD 00, BP-Energrease HTO, ESSO-Fibrax 370
Dispose of old lubricant in an environmentally-friendly manner.
14.5 Changing the rope
14.5.1 Changing the rope on the cable drum
Completely unwind the rope.
Remove the black plastic cover from the drum protector.
Loosen the rope clamping lug on both screws, pull out the rope and insert a new rope.
Tighten the rope clamping lug and close the plastic cover. Wind the rope up again cleanly
and evenly.
14.5.2 Changing the rope on rope weight
Remove one screw (4) on the non-twisting
device (1) and fold it to the side.
Push back the rope wedge (2), unscrew the
clamping screw (5) and pull out the rope.
Lead the new rope in from above through
the rope weight (3), make a loop, guide the
rope end back and horizontally through the
borehole.
NOTE
Do not allow the rope to project at the
circumference of the rope weight (3).
Firmly clamp the rope end with the clamping
screw (5) (hexagon socket size 3).
3
4
5
1
2
Fig. 25 Rope weight
Place the rope wedge (2) into the loop and pull the rope back only in the centre until rope
wedge is secure.
Flip back the non-twisting device (1) and re-fasten with the screw (4).
Measure sufficient rope length, as the last two rope windings must always
remain on the cable drum.
Assembly and Operating Manual
Page 29 of 38
BL107 GB Edition 01.2010