2.
GENERAL FEATURES
The GH10HA Controller is a microprocessor-based device manufactured using the Surface Mount
Technology (SMT).
It is designed to control the processes of Hot Utility Water (HUW) heating and the main Central
Heating (CH) water circuit. Control parameters can be adjusted to the current operating conditions and
boiler type. The Controller includes a system protecting from power outages and other different
disturbances.
The GH10HA Controller is fitted with:
•
inputs:
1.
Boiler output water temperature measurement (NTC sensor),
2.
Flue gas temperature sensor in chimney (PT1000 sensor),
3.
HUW boiler water /return water temperature measurement (NTC sensor),
4.
Door sensor – reed relay,
It also contains four outputs allowing direct connection of 230 V AC devices, i.e.: fan, CH circulation pump,
HUW pump or mixing pump, depending on the type of the controlled heating system (
⇒
section
6
, page
7
).
ALWAYS DISCONNECT THE CONTROLLER
FROM POWER DURING THUNDERSTORMS