Geco GA03HA-01 User Manual Download Page 2

  GA03HA-01

   User Manual                                                                                                        

PPUH „GECO” Sp. z o.o.                                  

Page 

 

2                                                               Edition I 

                Valid from 2017-07-26

 

Table of contents 

 

1.

 

INTRODUCTION .................................................................. 

BŁĄD! NIE ZDEFINIOWANO ZAKŁADKI. 

1.1. 

G

RAPHIC SYMBOLS

 ............................................................................ 

B

ŁĄD

!

 

N

IE ZDEFINIOWANO ZAKŁADKI

.

 

1.2. 

LCD

 LIGHT AND KEYBOARD FUNCTIONS

 ................................................. 

B

ŁĄD

!

 

N

IE ZDEFINIOWANO ZAKŁADKI

.

 

2.

 

OVERVIEW ......................................................................... 

BŁĄD! NIE ZDEFINIOWANO ZAKŁADKI. 

3.

 

Location and installation .................................................... 

BŁĄD! NIE ZDEFINIOWANO ZAKŁADKI.

 

4.

            

CONNECTION TO BOILER CONTROLLER ....................................................................................... 8 

5.

            

„QUICK START” FUNCTION ......................................................................................................... 9 

6

.           

OPERATING GA03HA-01 ............................................................................................................ 10 

6.1. 

C

ONTROLLER MAIN SCREEN

 ................................................................. 

B

ŁĄD

!

 

N

IE ZDEFINIOWANO ZAKŁADKI

.

 

6.2. 

F

AST ACCESS KEYS

 .............................................................................................................................. 10 

6.2.1.      Preview of controller operations ......................................................................................... 11 
6.2.2.      Change work mode ............................................................................................................. 12 
6.2.3.      Heating mode...................................................................................................................... 13 
6.2.4.      Daily settings ....................................................................................................................... 13 
6.2.5.      Weekly settings ................................................................................................................... 14 
6.2.6.      H

ELP

 ..................................................................................................................................... 14 

6.3.

      GA03HA-01

 ROOM PANEL MENU

 .................................................................................................................. 16 

6.4.

      

U

SER SETTINGS

 ................................................................................................................................... 17 

6.4.1.      Timer settings ..................................................................................................................... 18 
6.4.2.      Edit temperature ................................................................................................................. 18 
6.4.3.      Work mode.......................................................................................................................... 19 
6.4.4.      Temperature regulation ...................................................................................................... 20 
6.4.5.      Factory settings ................................................................................................................... 21 

6.5.

      

S

ETTINGS PANEL

 ................................................................................................................................. 21 

6.5.1.      Choose language ................................................................................................................. 21 
6.5.2.      D

ate and time

 ......................................................................................................................... 22 

6.6.

      

O

PERATION HISTORY

 ........................................................................................................................... 23 

6.6.1.      Alarms and warnings .......................................................................................................... 23 
6.6.2.      Boiler working time ............................................................................................................. 24 
6.6.3.      Time operating in safe mode  ............................................................................................. 24 
6.6.4.      Number of times maximum temperature exceeded ........................................................... 24 
6.6.5.      Power failure ....................................................................................................................... 25 

6.7.

      

O

PERATION PREVIEW

 .......................................................................................................................... 25 

7.

 

TYPES OF ALARMS AND WARNINGS ......................................................................................... 25

 

8.

 

INFORMATION ON THE DISPOSAL AND COLLECTION OF WORN OUT ELECTRICAL AND ELECTRONIC 
EQUIPMENT ............................................................................................................................ 30

 

9.

 

NOTES ..................................................................................................................................... 30

 

1.

 

Introduction 

Summary of Contents for GA03HA-01

Page 1: ...ing with heating regulator Programme version 01a USER MANUAL We request that users carefully study applicable Instructions before connecting and starting up any of our products Should any doubts arise...

Page 2: ...operations 11 6 2 2 Change work mode 12 6 2 3 Heating mode 13 6 2 4 Daily settings 13 6 2 5 Weekly settings 14 6 2 6 HELP 14 6 3 GA03HA 01 ROOM PANEL MENU 16 6 4 USER SETTINGS 17 6 4 1 Timer settings...

Page 3: ...tuations and have the following graphic forms Warning This symbol is used when it is necessary to follow the sequence of operations as described in the instructions Any error or failure to follow the...

Page 4: ...ard functions ON OFF Increase maximum temperature one step Weekly settings Panel controller connection Power ALARM Daytime temperature Night time temperature Change work mode Preview work of devices a...

Page 5: ...devices current measured temperature and accompanying functions Fast access to daily settings Daily settings screen is shown Fast access to weekly settings Weekly settings screen is shown Enter panel...

Page 6: ...boiler from the home Using the room panel as an interface with the controller mounted on the boiler makes the controller distinctly more convenient to use The GA03HA 01 room panel has a built in sens...

Page 7: ...ure reading applicable to the entire area to be heated Fig 1 Examples of correct and incorrect locations for the GA03HA room panel Installing the GA03HA 01 room panel on the wall Step 1 Step 2 Step 3...

Page 8: ...supply Below is a detailed description for connecting the room panel to the controller Poni ej przedstawiony zosta dok adny opis pod czenia panelu z regulatorem A detailed description of connection a...

Page 9: ...he room panel as well as the loss of the icons on the controller main screen when the power is disconnected for 15 seconds 5 Quick start Function When the room panel is connected to the boiler control...

Page 10: ...has the following fast access keys These keys allow amongst other things easy and intuitive previews of current temperature measured by the boiler controller changes to the controller mode help inform...

Page 11: ...the heating system Pressing the button takes you to the next screen a preview of the temperatures measured by the boiler Cursors indicate the selected temperature there are two wide cursors on each si...

Page 12: ...disappears and the hourly heating cycle is not distinguished the bar at the bottom of the screen indicates the heating cycle If the controller is already in manual mode it enters automatic mode This...

Page 13: ...e edited but the remaining seven can be set by the user according to requirements Use the buttons or to select the item for editing programme number or daytime or night time temperature The item for e...

Page 14: ...cursor Heating temperatures change according to changes in the programme The transition between days of the week is looped Return to the previous level without activating changes by pressing If daily...

Page 15: ...scriptions of all icons Pressing the button while an alarm is active displays service data The screen will display information including room panel model programme number and telephone contact informa...

Page 16: ...1 4 1 Standard stabilization 1 4 2 Factory settings 1 5 Panel setting 2 PA PA PANELU 2 Language selection 2 1 Time and date 2 2 Work history 3 Alarms and warnings 3 1 Boiler operation time 3 2 Time o...

Page 17: ...mperature according to heating configuration change work mode change temperature regulation and restore factory settings Scroll through the user menu using the buttons or 6 4 1 Time settings The user...

Page 18: ...re in the boiler The range of stabilization factor is from 1 to 6 6 4 2 Edit temperature By entering this submenu it is possible to choose the temperature value which can be set Access to temperatures...

Page 19: ...mode use the keys or and the selected work mode will be highlighted The selected mode will appear on the screen after pressing the button If the previous mode was automatic and you would like to selec...

Page 20: ...If you would like to change the temperature regulation select one using the keys or and the selected type of regulation will be highlighted Press the button to display the chosen regulation on the scr...

Page 21: ...set the language according to preference and edit the time and date Select your chosen option using or The selected option is highlighted and can be accessed by pressing the button 6 5 1 Choose langu...

Page 22: ...and date To set the time and date choose the position Time and date and confirm by pressing the button The screen now displays the fields for editing The current value for editing will be highlighted...

Page 23: ...rnings In this menu the user can preview the seven most recent alarms and warnings If more than seven have been recorded the latest information overwrites earlier data Information is displayed in orde...

Page 24: ...ating in safe mode In this place it is possible to see the number of hours in which the controller worked in safe mode To exit to the previous menu press 6 6 4 Number of times maximum temperature has...

Page 25: ...int 6 2 1 in the section fast access key 7 Types of alarms and warnings In the case of any kind of boiler controller warning or alarm this information will be displayed on both the controller and the...

Page 26: ...age to a sensor which may have a direct impact on the safe operation of the boiler the user can choose to change the system configuration and continue operation without this sensor This decision must...

Page 27: ...switches automatically to work without the hot water returning water function ALARM 4 Damage to sensor for hot water temperature water returning to boiler Using the HELP button shows technician date a...

Page 28: ...formed The HELP button displays technician data and the Anti Legionella function is switched off ALARM 11 Maximum feeder temperature exceeded The controller is disabled during this alarm and an alarm...

Page 29: ...rn out electrical and electronic equipment Caution This symbol placed on the product or its packaging indicates the need for selective collection of worn out electrical and electronic equipment It mea...

Page 30: ...GA03HA 01 User Manual PPUH GECO Sp z o o Page 30 Edition I Valid from 2017 07 26 9 NOTES...

Page 31: ...GA03HA 01 User Manual PPUH GECO Sp z o o Page 31 Edition I Valid from 2017 07 26...

Page 32: ...P P U H Geco Sp z o o Cholerzyn 376 32 060 Liszki tel 012 6369811 6361290 fax 012 6362002 http www geco pl e mail geco geco pl...

Reviews: