Installation

 

 

In order to guarantee the housing protection class IP66 (Nema 4X), the display must 

be installed in a housing with a certificate of at least IP66 (with a cross-section of 
417mm x 328.5mm or 16.43“ x 12.95“).  
 
The display is placed in the housing section with the front side facing outwards and is 

mounted from within in such a way that that module lies closely upon it, with the help 
of fastening pins which are evenly spaced over the outer display housing.  
 

 

 

Terminal connections

 

 
 

Connection 

Meaning 

K1, K2, K3 

Supply circuits  

K4 

For the connection of ASDs* 

K5 

For the connection of a transmission unit  

K9 

For the connection of ASDs* 

X2 

Video input UVI 

 

* ASD: Application Supporting Device

   

 

The terminal notation / numbering should be taken from the terminal nameplate which is 

attached close to the terminal. 

 

Details should be taken from the authorisation.  

 
 

Summary of Contents for Challenger 15i-2-HB-FMO UVI

Page 1: ...GECMA COMPONENTS GMBH WWW GECMA COM TEL 49 2237 6996 MANUAL HB DISPLAYREV C EN DOC 31 01 07 A J 1 Operating Instructions CHALLENGER 15i 2 HB FMO HighBrightnessDisplay ...

Page 2: ... is distinguished by its particular luminous intensity of up to 650cd m In order to be able to display graphics from a PC for instance a transmission unit e g Challenger TCV2i is required Distances of several hundred metres between the display and the transmission unit can be realised A suitable electrical power unit e g PSU14i 8 543 is required for the energy supply e g PSU14i 8 543 Models of the...

Page 3: ...H for repair should be accompanied by a of description of the fault encountered Please ensure that the following steps are taken prior to despatching the unit for repair Remove all residual media paying particular attention to possible traces of medium in sealing grooves and gaps Please refrain from returning the unit if you are not absolutely certain that you have been able to remove every trace ...

Page 4: ...ounted from within in such a way that that module lies closely upon it with the help of fastening pins which are evenly spaced over the outer display housing Terminal connections Connection Meaning K1 K2 K3 Supply circuits K4 For the connection of ASDs K5 For the connection of a transmission unit K9 For the connection of ASDs X2 Video input UVI ASD Application Supporting Device The terminal notati...

Page 5: ... 0 5 2 5 mm rigid flexible Terminal strip K1 supply circuits Terminals 3 4 5 6 7 8 11 12 13 14 and 15 16 Values per circuit Voltage Ui DC 12 5 V Current Ii 543 mA Power Pi 6 8 W effective internal capacitance Ci negligible effective internal inductivity Li negligible Terminal strip K2 and K3 supply circuits Terminals 1 2 Values per circuit Voltage Ui DC 12 5 V Current Ii 543 mA Power Pi 6 8 W effe...

Page 6: ... to 7 for the connection of an ASD application supporting device for data input output e g a keyboard Voltage Uo DC 5 5 V Current Io 71 mA Max external capacitance Co 40 uF Max external inductivity Lo 1 mH Plug connection X2 UVI video input BNC connector Voltage Uo 2 5 V Current Io 88 mA Power Po 176 mW Max external capacitance Co 100 uF Max external inductivity Lo 4 mH for the connection of an in...

Page 7: ... If the device is to be exchanged while being used in a dusty atmosphere the device or the case in which the device is installed must first have its power switched off and if necessary be allowed to cool according to regulations Before you open the device or case and while the device or case is open the environment of the device or case must be kept dust free as far as possible so that no dust can...

Page 8: ......