background image

Quick Reference Card

The system will automatically perform one daily filter cycle. During a filter cycle:
•  If present, Pump 2 and/or blower run(s) for one minute, then
•  Pump 1 runs at low speed for the programmed number of hours, and the ozonator is turned on.

To set the filter cycle duration:

PROBLEMS & CORRECTIVE ACTIONS

The pump starts by itself 
for one minute on several
occasions and the "Filter Cycle"
marker is flashing.

Not a bug but a feature!

The

 Smart Winter Mode 

of the spa pack protects

your spa from the cold by turning the pump on for
one minute several times a day to prevent the water
from freezing in the pipes.

The "HL" error message is 
displayed.

The "HL" error message is
flashing.

The system has shut the heater down because the
water temperature 

at the heater

 has reached 48˚C

(119˚F).

The system has shut down because the water
temperature 

in the spa

 has reached 44˚C (112˚F).

Only the 

Smart Winter Mode 

remains active.

In both cases, do not enter the water! Remove spa
cover and allow the water to cool down to 40˚C
(104˚F), then turn the breaker off to reset the system.
Call your dealer or service supplier if the problem
persists.

The "FLO" error message is 
displayed.

The system does not detect any water pressure when 
the pump is turned on.

Check and open water valves. Check for water level. 
Clean filter. Call your dealer or service supplier if the
problem persists.

The "FLC" error message is 
displayed.

The system detects a problem with the pressure switch. 
Call your dealer or service supplier.

The "Prr" error message is
displayed.

The system detects a problem with the temperature
probe. Call your dealer or service supplier.

The display is flashing.

A power failure has occurred. Press any key to reset
the system, then reprogram all desired parameters.

9919-100185

1.800.78.GECKO

• E

Q U

I P P

E D W

I T H G E C K O ' S E X C L

U S I V

E •

Smart

Winter

Mode

 

TM

GECKO

Press and hold the

Light

 key for 5 seconds.

The display will show "F xx"

where "xx" represents the 

currently set filter cycle

duration in hours.

When the desired setting is 

displayed, press the 

Light

 key 

to confirm.

The display will then show 

"d xx" where "xx" represents 

the delay between the moment 

the filter cycle duration was 

programmed and the time it 

will be scheduled to start.

Use the 

Up

 or 

Down

 arrow 

key to change the setting.

0   = no filter cycle 

24 = continuous filter cycle

Use the 

Up

 or 

Down

 arrow 

key to change the setting.

0 = cycle starts now 

x = cycle will start in "x" hours

The "Filter Cycle" marker 

will be displayed during a 

filter cycle.

HOW TO PROGRAM THE FILTER CYCLE DURATION

An irregularly flashing "Filter Cycle" marker indicates that the
system has stopped filtering after 3 hours because the water
temperature exceeds the set point by more than 1˚C (2˚F).
If the temperature cools down to 0.5˚C (1˚F) above set point
before the scheduled end of the cycle, filtering will resume for 
the remaining of the programmed duration.

Note: After a power failure, the filter cycle duration 

will return to its default value (2 hours). In this case, 

the first filter cycle will start 12 hours after power has 

been restored.