
MC-MP-SBD O wner’s Manual
36
Filter Cycle
(Continuation)
40-minute filter cycle time-out:
• If a pump, blower or light is turned on during a filter cycle, the
cycle will be interrupted and will only be resumed 40 minutes
after the last active output has been turned off. The "Filter"
indicator will flash during the 40-minute time-out.
Purge cycle:
• The system automatically performs 6 purge cycles per day, at
4 hours intervals. During a purge cycle, the following sequence
is executed:
• Pumps 2 & blower run at high speed for 1 minute.
• Pump 1 will then run for 1 minute.
To program a purge cycle:
• Press
Filter
key.
• The display will show "P xx",
with "xx" representing the current
set purge cycle frequency.
• Use
Up
&
Down
keys to
set the number of purge cycles per day:
1 = once a day,
24 = every
hour.
W hen setting is displayed:
a) If no key is pressed for 5 seconds the new setting will be saved,
but it will be effective until the next cycle.
b) If filter key is pressed, a purge cycle will start immediately.
The "Filter" indicator will light up on the display when the purge
cycle is on.
M C-M P-SBD Operation and Functions
Operating Instructions
Summary of Contents for M-CLASS MC-MP-SBD
Page 7: ...Notes...
Page 27: ...MC MP SBD Owner s Manual 26 Notes...
Page 29: ...MC MP SBD Owner s Manual 28 Notes...
Page 31: ...MC MP SBD Owner s Manual 30 Notes...
Page 41: ...MC MP SBD Owner s Manual 40 Notes...