Gecko M-CLASS MC-MP-SBD Owner'S Manual Download Page 1

CLEARLY ADVANCED SPA SYSTEMS!

O

WNER'S MANUAL

MC-MP-SBD SPA SYSTEMS

INSTALLATION, INSTRUCTIONS & MORE!

TAKING OVER THE WAVES!

Summary of Contents for M-CLASS MC-MP-SBD

Page 1: ...CLEARLY ADVANCED SPA SYSTEMS OWNER S MANUAL MC MP SBD SPA SYSTEMS INSTALLATION INSTRUCTIONS MORE TAKING OVER THE WAVES...

Page 2: ...l Temperature Probe Holder 20 J umper Set Up 21 Keypad Temperature Probe 23 Connecting Your MC MP SBD 24 Programming Low Level Programming 25 Output Connections Set Up Connecting Outputs 27 Electrical...

Page 3: ...ion Pump 39 Power Up Detection 39 Smart Winter Mode 39 Temperature Display Unit 39 Alarm Error Displays Alarm Displays 41 Error Displays 42 W iring Diagram Wiring Diagram 43 Miscellaneous Factory Defa...

Page 4: ...t cable should alwaysbe secured in place with aproper strain relief A notice should be installed by the manufacturer on the finished product to notify the end user to alwayscheck the water temperature...

Page 5: ...erature rating specified by SpaBuildersSystemsGroup Inc The spaelements containing water exposed to cold air piping pumps valves etc must be approximately at the same ambient temperature asthe power m...

Page 6: ...nduction control shall be closed A blower that heatsthe water if provided shall be operated The resultsare acceptable if the water at any tub inlet doesnot exceed 50 C 122 F Any ventilation openingson...

Page 7: ...Notes...

Page 8: ...unclear to you If so please contact usand one of our agentswill be glad to answer all of your questions You can phone usat our toll free number at 1 866 639 7274 or fax us at 1 909 667 2902 Or if you...

Page 9: ...nual Total current ouput cannot exceed total input rating RISK OF ELECTRICAL SHOCK Install at least 5 feet 1 5 m from any metal surface Do not allow any electrical appliance within 5 feet 1 5 m of the...

Page 10: ...de panel Sensor failure detection Programmable filter cycles High Limit protection Pressure switch failure detection Current limiting option Smart Winter Mode Temperature measurement within 1 F 0 5 C...

Page 11: ...A 240 VAC 16 7 A 4 kW 120 VAC 3 A 12 VAC 1 A 120 VAC 2 A Pump 1 2 Blower Heater T emperature Operating 0 Fto 122 F 17 C to 50 C 40 Fto 160 F 40 C to 70 C Up to 80 non condensing Adjustable in 1 increm...

Page 12: ...also available The K 3 is useful for large spas offering access to the basic functions only All top side controls are sealed to watertight perfection ensur ing years of trouble free operation Attentio...

Page 13: ...box can easily be removed Simply loosen the 4 front cover screwsto access connectorsand jumpers Remove the plastic cover to access main board Removable Cover Warning Mounting feet Heater Specificatio...

Page 14: ...and rubbing alcohol First peel off the plastic film that protectsthe LED display window Please note that the following installation procedure is similar for K 8 and K 3 pack overlays Make sure to sele...

Page 15: ...at the surface of the keypad Peel the protective paper from the overlay Place the overlay on the keypad starting with itsleft side Make sure the overlay iswell aligned and restsperfectly in the recess...

Page 16: ...d and the keypad should be replaced immediately 1 Select the most appropriate location for the keypad 2 Cut out a 2 5 8 x 6 3 8 67 x 162 mm rectangular opening from the edge of the spa Clean surface 3...

Page 17: ...ting cable hanging below opening 5 a If installing keypad from above if overlay hasnot been placed use aPhillipsscrewdriver to tighten in place and properly seal unit avoid overtightening Bracketsfoll...

Page 18: ...ontrol keypad 2 Drill two 1 25 mm holesat 2 5 8 66 mm from center to center asillustrated opposite Cut the materialbet ween the two holes 3 Peel off the double sided tape protective layer on the back...

Page 19: ...th casesaspecial plastic guide plate facilitates installation Power Box Installation 1 Select most appropriate location on floor for spapack and firmly attach guide plate to wooden base with 3 standar...

Page 20: ...ll for spapack and attach guide plate to wall with 3 standard screws 2 Slide bottom of pack into place by positioning it over the two brackets on top edge of guide plate It should slide into place eas...

Page 21: ...ly accessible location as close to the pack aspossible 2 Drill a7 8 22 mm diameter hole in the spawall 3 Assemble and install holder to spawall Turn nut counter clockwise tightly enough to prevent wat...

Page 22: ...on the board or by setting the low level programming To access the jumpers 2 To change asetting simply pull jumper off and replace in desired position see jumper set up posi tions 1 The jumpersare loc...

Page 23: ...me time Position 1 HC The heater may be turned on when both pumpsare operating at high speed Position 2 LC The heater may NOT be turned on if ANY pump 1 or 2 ison at high speed The Heater indicator wi...

Page 24: ...below Connecting to the Power Box Warning Keypad cable Keypad Power box Clearance between low and high voltage conductors must be at least 1 4 6 mm Connecting the Temperature Probe The water temperatu...

Page 25: ...nnected to your spa s plumbing Make connectionsto the tail pieceslocated on each side of the heater tube Connectionsmust be perfectly sealed Refer to your spamanual for more information on how to prop...

Page 26: ...A Low level programming To access low level programming press and hold On Off key for 20 seconds the first parameter s code should appear on the display Use Up Down keys to modify parameter values and...

Page 27: ...MC MP SBD Owner s Manual 26 Notes...

Page 28: ...ective connectors Connectorsare located on the left side of the pack for the horizontal heater model They are clearly identified Your MC MP SBD also comeswith alight socket that is ready to receive al...

Page 29: ...MC MP SBD Owner s Manual 28 Notes...

Page 30: ...diagramssupplied Remember Connectionsmust be made by a certified electrician W arning Total current ouput cannot exceed total input rating Electrical box GFCI Pack terminal block 240 VAC input supply...

Page 31: ...MC MP SBD Owner s Manual 30 Notes...

Page 32: ...minute delay Pump keysare used to turn Pump 1 Pump 2 on or off and to select be tween low and high speeds PressPump 1or Pump 2 to turn Pump 1or 2 on at low speed Pressasecond time to change to high s...

Page 33: ...5 unlessyou turn it off manually The Light key isused to turn the light on or off and to select between low and high intensities PressLight once to turn light on at high intensity Pressasecond time to...

Page 34: ...l flash A built in timer will turn the fiber box off after 2 hours unlessyou turn it off manually first MC MP SBD Operation and Functions Up Down Arrow Keys Up Down keysare used to set the temperature...

Page 35: ...minute Pump 1 will then run at low speed for the programmed length of time see next page MC MP SBD Operation and Functions If water temperature falls 1 F 0 5 C lower than the Set Point the heater aut...

Page 36: ...ration To program filter cycle duration PressFilter key The display will show Fd xx with xx representing the current set filter cycle duration in hours Use Up Down keysto set the number of hours 00 no...

Page 37: ...sequence isexecuted Pumps2 blower run at high speed for 1 minute Pump 1 will then run for 1 minute To program a purge cycle PressFilter key The display will show Pxx with xx representing the current...

Page 38: ...CP message isdisplayed for 1 second To Fully lock the keypad Pressand hold Pump 1key for 10 seconds If properly programmed the LOCF message will appear briefly on the display In this mode only automat...

Page 39: ...simple key presssequence invertsthe display to make it readable from inside or outside the spa To invert the display Pressand hold Filter key for 5 sec onds Please note that in inverted mode some icon...

Page 40: ...secondsto allow heater to cool down Following apower failure the display panel will continue flashing until any key ispressed Thisfeature notifiesyou that apower failure hasoccurred The MC MP SBD ise...

Page 41: ...MC MP SBD Owner s Manual 40 Notes...

Page 42: ...r indicator is flashing Also see page 36 Not a bug but a feature Thisindicatesthat either a the filter cycle isin a40 minute time out to avoid ozonator activation while the spaisbeing used or b the sy...

Page 43: ...the water Check and open water valves Clean filter if necessary Check water level Add water if necessary Shut power off and power your spaup again to reset the system Call your dealer or service suppl...

Page 44: ...tage 120 v 240 v Green Ground P70 P70 Red Low Speed P22 P22 Black High Speed P35 P35 White Com P45 P58 Jumper Settings Refer to page 8 Blower Voltage 120 v 240 v Green Ground P72 P72 Black Line P43 P4...

Page 45: ...MC MP SBD Owner s Manual 44 Notes...

Page 46: ...ator 120 VAC output Circ pump 120 VAC output Blower 120 VAC output Light 12 VAC output Heater 240 VAC output Fiber box 120 VAC output Water temperature at 95 F 35 C Normal Mode Fahrenheit F temperatur...

Page 47: ...T H G E C K O S E X C L U S I V E Smart Winter Mode TM CLEARLY ADVANCED SPA SYSTEMS For more information about our spa packs and all our other products and services visit our web site at www sbsg equ...