background image

INSTALLATION AND MOUNTING 

INSTALLATION AND MOUNTING 

MOUNTING

MOUNTING

The GECKO® GENESIS ELEGANCE C.R.I.S.T.A.L.® Audiophile Class-H power amplifiers are 2U standard 
rack  space  units.  All  mountable  in  standard  19”  rack.  4  front-panel  mounting  points  and  4  rear-panel 
mounting points with M3 thread size are provided on each amplifier. Rear mounting gives additional support, 
and the use of rear support is highly recommended in all mobile and touring sound systems.  

COOLING

COOLING

The amplifier uses a  forced-air cooling  system  with  air flow from  front to  rear,  maintaining a low  operating  
temperature  within  defined  limits.  Front-to-rear  air-flow  is  preferred  as  cooler  air  is  present  at  the  front  in 
nearly all applications (this allows higher continuous power levels without encountering thermal problems). 
Never attempt to reverse the air flow. The amplifier modules require a pressure chamber between the fans 
and heatsink, and this effect functions only in one direction. 

Make sure that there is an adequate air supply in front of the amplifier, and that the rear of the amplifier has 
sufficient space to allow the exhaust to escape. If the amplifier is rack-mounted, do not use covers or doors  
on the front or rear of the rack when it is in operation.

Always make sure that the dust-filters behind the detachable front panel air cooling vents are clean to ensure 
maximum possible air flow. 

OPERATING VOLTAGE

OPERATING VOLTAGE

The label print above the mains cable on the rear of the amplifier indicates the AC mains voltage for which 
the  amplifier  is  wired  and  approved:  110V  or  240V.  Connect  the  power  cable  only  to  the  AC  source  type  
referred to on the print. The warranty will not cover damage caused by connecting to an incorrect type of AC  
mains.

 

Once a suitable AC supply is connected, the amplifier can be turned on using the front panel power switch.  
The amplifier then goes through a soft-start sequence as it self-checks its circuits. The fans will blow at high  
speed before dropping to idle, and the “PWR” LED will illuminate. 

Inrush  power  is  controlled  and  limited  during  “soft-start”,  enabling  multiple  amplifiers  to  be  powered  up 
simultaneously. 

______________________________________________________________________________________

12

12

© GECKO MUSIC GROUP. All Rights Reserved.

NOTES:  I

f  the  amplifier  malfunctions  due  to  dirty  dust-filters,  any  required  repairs

are not covered by the warranty.

Summary of Contents for genesis elegance age 600H

Page 1: ...GECKO GENESIS ELEGANCE AGE 600H AGE 900H www geckomusic net www geckomusic net OWNER S MANUAL OWNER S MANUAL...

Page 2: ...other A grounding type plug has two blades and a third grounding prong The wide blade or the grounding prong is provided for your safety If the provided plug does not fit into your outlet consult an e...

Page 3: ...To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pressure levels use hearing prote...

Page 4: ...d at a fraction of a premium Our engineering team is constantly doing research and development to meet this objective We thank God that by HIS grace we have succeeded in developing the revolutionary C...

Page 5: ...OUNTING 12 SPECIFICATIONS 13 WARRANTY 14 ______________________________________________________________________________________ GECKO MUSIC GROUP All Rights Reserved NOTES This manual covers the GECKO...

Page 6: ...chnology SMT ensuring exceptional efficiency and reliability The GENESIS ELEGANCE is equipped with advanced system protections such as the automatic Voltage Peak Limiter VPL for protecting input signa...

Page 7: ...GE CONTENTS GENESIS ELEGANCE AGE 600H AGE 900H 4 conductor screw terminal adaptor Rubber feet ______________________________________________________________________________________ 2 2 GECKO MUSIC GRO...

Page 8: ...tenuator control is disabled in BRIDGE PARALLEL mode ______________________________________________________________________________________ 3 3 GECKO MUSIC GROUP All Rights Reserved 7 1 7 8 8 3 2 4 4...

Page 9: ...Illuminates when Voltage Peak Limiter VPL is active to regulate clipping CPL ORANGE LED Illuminates when Current Peak Limiter CPL is active to regulate amplifier s output current so that it does not e...

Page 10: ...rovided one per channel 12 LINK 1 2 Two balanced XLR male type LINK sockets are provided one per channel to loop thru signal from one amplifier to another 13 MODE SELECTOR Select the desired INPUT con...

Page 11: ...with black insulator Plug in the adaptor into the sockets when ready 16 FUSED IEC AC POWER CORD WITH PLUGTOP Plug the AC power cord into a standard wall power outlet The fused plugtop protects the amp...

Page 12: ...eratures keeping fan noise to a minimum Under extreme thermal load the fans will force a very large volume of air through the heat sinks If the heat sinks surpass the maximum allowed temperature the U...

Page 13: ...the VHF protection circuit mutes the output signal VHF LED indicator illuminates After five seconds the outputs will un mute and return to normal operation VHF LED indicator light goes off unless the...

Page 14: ...e AIR COOLING VENTS FILTERS CLEANING AIR COOLING VENTS FILTERS CLEANING Step 1 Check that your amplifier is switched off Clean the front air cooling vents using a vacuum cleaner Step 2 Turn the quick...

Page 15: ...lifier s CHANNEL A and CHANNEL B attenuators are set all the way down to inf 2 Make connections using only quality audiophile signal cables e g GECKO TRUTH T3AL audiophile speaker cables e g GECKO TRU...

Page 16: ...below 4 CONDUCTOR SCREW TERMINAL ADAPTOR 4 CONDUCTOR SCREW TERMINAL ADAPTOR WIRING SCHEMATIC WIRING SCHEMATIC SPEAKON SPEAKON WIRING SCHEMATIC WIRING SCHEMATIC ________________________________________...

Page 17: ...ce to allow the exhaust to escape If the amplifier is rack mounted do not use covers or doors on the front or rear of the rack when it is in operation Always make sure that the dust filters behind the...

Page 18: ...nd RF Connectors Input XLR Female 2 Link XLR Male 2 Output 4 Pole SPEAKON 2 4 Conductor Screw Terminal Socket Power Supply Built In Power Supply choose either 110V or 240V 50 60Hz model Physical Prope...

Page 19: ...ce manuals 4 Connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the product is used 5 Damages defects caused b...

Page 20: ...freight and packing Such costs will also be invoiced separately when the buyer has sent in a written repair order WARRANTY RIGHTS This warranty is exclusive and extended to the original buyer and is...

Reviews: