INSTALLATION 

WARNINGS 

(MAY CAUSE SERIOUS INJURIES OR DEATH)

 

 

The power supply must be turned off during the installation process. 

 

This pump is wired for 115 VAC, 60 Hz, and Single Phase power 
supply only.  The power supply should be supplied through a Ground 
Fault Circuit Interrupter (GFCI) with a rated tripping current not 
exceeding 5 mA. 

 

No part of the pump is to be located above the jetted bath during 
use.  Parts incorporating electrical components, except remote 
control devices, must be located or fixed so that they cannot fall into 
the jetted bath. 

 

Pump and other parts containing energized or live parts, except parts 
supplied with safety extra low voltage not exceeding 12 V, must be 
INACCESSIBLE to a person in the jetted bath. 

 

Pump must be mounted INDOORS on top of a horizontal and solid 
surface; fixed securely using screws or bolts through the 4 mounting 
holes located on the base. 

 

This pump is not intended for use by young children or infirm 
persons without supervision. 

 

Young children should be supervised to ensure that they do not play 
with the unit. 

 

CAUTION 

(MAY CAUSE PROPERTY DAMAGE

 

This pump is intended for

 

Jetted Bath use ONLY, 

and is not 

suitable for any other application. 

 

DO NOT run the pump without water.  This

 

may damage pump and 

its components.

 

 

1.  Be sure that the requirements under Mounting Preparation section 

have been met.  

2. The pump is provided with barrel unions to connect the pump’s 

Suction port (inlet) and Discharge port (outlet) to the plumbing.  The 
plumbing must be routed or oriented in a way that when the pump is 
installed, the port connections are not subjected to undue stress. 

 
 
 
 

 
 

 