2. This pump is intended for permanent installation only and must
not be used in portable service application. The mounting
surface must be constructed from durable material and
supported securely in a horizontal position.
3. A clearance of at least 7.5 cm (3”) on all sides (top, sides, front,
and back) is required for ease of installation and air circulation.
Enclosures must be adequately ventilated to promote free flow of
air and prevent condensation.
4. Provision for securing the plumbing leading to the pump must be
considered to avoid undue stress to the pump’s connections.
5. The pump requires 115 Volts A.C., 15 amperes minimum, 60 Hz,
single-phase power supply supplied through a Ground Fault
Circuit Interrupter (GFCI) with a rated tripping current not
exceeding 5 mA.
Above are the minimum requirements required for installing this pump.
Additional requirements, standards, and codes, mandated by
government agencies on specific areas where the pump will be installed,
must be followed
.
5.9“
151 mm
8.1“
206 mm
13.7“
340 mm
SUCTION
PORT
DISCHARGE
PORT
AIR SWITCH
MOUNTING BASE
Disc harge plumbing slightly angled to bleed air.
Suc tion plumbing slightly angled to enable
water to drain out from pump when switched off.
TO BATH’S JET
TO BATH’S SUCTIO
N