INSTALLATION INSTRUCTIONS
WIRING
All wiring for the installation of this unit should be done by a licensed electrician according to
National and Local Electrical Regulations.
SINGLE PHASE MOTOR UNITS
All single-phase motors are wired for proper direction of rotation. Unless otherwise requested
motors are wired for low voltage service.
VAPOR OIL PUMPS
Use a 10W-30 Oil for all Conde Vapor Oil Pumps. When starting new vapor oil pumps, fill oil
reservoir above the fittings in which the wicks are inserted. This will give the Pump extra oil for
the first two hours of operation.
When refilling, fill to just below oil wicks.
Capacities:
Model 3………..1 quart Maximum.
VACUUM RELIEF VALVE
The vacuum relief valve is factory preset at 10in/hg, do not exceed.
OPERATIONAL LIMITS
Max Vacuum (Continuous) 15IN/Hg
Max Vacuum (Intermittent) 25IN/Hg