background image

from 1/2” to DN100

MAINTENANCE

The solenoid valve’s operation should be checked periodically. Should disassembly be necessary, make sure there is no gas under pressure
inside the valve and that is not connected to the power supply before starting. All maintenance operations should be carried out by qualified
personnel.

: a particular (230Vca) connector must be used with these
coils which acts as a “delayer” and “rectifier” included in the
packaging: Cod. 2.180.2429

COIL MARKING

N.C.

        

230Vac

230VRAC 17W

B

ELECTRICAL CONNECTION

NEUTRAL

EARTH

PHASE

110Vac

110VRAC 17.5W

B

B

LOSS OF HEAD DIAGRAM

NO

Overall measurements (mm)
Threaded connections:  from 1/2” to 2”
as ISO 228/1. Alluminium body
Flanging connections: from DN65 to
DN100 as UNI 2229.

 

 Alluminium body.

INSTALLATION AND POSITION

Please caerfully read all istruction before use.
A suitable Gas filter (according to UNI EN161) must be installed upstream of this device and all rules and laws in force for Gas installations must
be adhered to.
These solenoid valves will only operate with when the flow is in the same direction as the arrow on the valve body which is generally towards   the
appliance and upstream of the regulation apparatus.

from 360mbar to 6bar

DIMENSIONS (mm):

C

72
72
72

164
164
164
247
247
265

B

68.0
68.0
68.0

154.5
154.5
154.5

185
200
220

A

148
148
148
240
240
253
350
350
385

φφφφφ

DN15 -1/2”

DN20 - 3/4”

DN25 - 1”

DN32 - 1”

1/4

DN40 - 1”

1/2

DN50 - 2”

DN65
DN80

DN100

Connection

Horizontal position

Vertical position

Overturned position

The manufacturer reserves the right to make any aesthetic or functional

modification to the product without prior notice at any time.

 dis.8034076b   cod. 2.710.2752

          

  

Made in ItalyMade in ItalyMade in ItalyMade in ItalyMade in Italy

TECHNICAL CHARACTERISTICS

- Max pressure:

360mbar-6bar

- Opening time:

<  1  sec.

- Closing time:

< 1 sec

- Max number of operations: 20 per minute
-  Power supply:

230Vac/110Vac (-15%+10%) 50-60Hz

- Use:

Non Aggressive gases (Family 1-2-3) and Air

- Working temperature:

-20°C..... +60°C.

- Connections:

from 1/2” to 2” threaded as ISO 228/1
from DN65” to DN100 flanging as UNI2223

- Degree of protection:

IP65

- Group:

2

- Approval:

Directive 2014/68/UE (only for  6bar model)
Directive 2009/142/CE (GAS)-EN161

12345678

12345678

12345678

12

12

12

12

12

12

Tecnocontrol Srl
via Miglioli, n°47
20090 Segrate (MI) Italy
Tel. +39 02 26922890
www.tecnocontrol.it

GECA Srl
via E.Fermi, n°98
25064 Gussago (BS) Italy
Tel. +39 030 3730218
www.gecasrl.it

Summary of Contents for AV015FO

Page 1: ...manutenzione del prodotto deve essere eseguita da personale qualificato ELETTROVALVOLE AUTOMATICHE APERTURA CHIUSURA RAPIDA da 1 2 a DN100 360mbar 6bar REGOLAZIONE PORTATA Nei modelli FR Flow regulation è possibile regolare la portata dell elettrovalvola La regolazione viene effettuata ruotando con un cacciavite il Perno di regolazione Svitare e togliere il Tappo fissaggio bobina Per AUMENTARE la ...

Page 2: ...datore e raddrizzatore presente nel l imballo TIMBRATURA BOBINA N C 230Vac 230VRAC 17W B COLLEGAMENTO ELETTRICO NEUTRO TERRA FASE 110Vac 110VRAC 17 5W B B DIAGRAMMA PERDITE DI CARICO NO Misure d ingombro in mm Attacchi filettati da 1 2 a 2 secondo ISO 228 1 Corpo in alluminio Attacchi flangiati da DN65 a DN100 se condo UNI 2223 Corpo in alluminio DIMENSIONI mm A 148 148 148 240 240 253 350 350 385...

Page 3: ...automatically reset to the closed position and will not reopen until the power to the coil in resumed Model with code FR have flow regulation 2 5 3 4 1 6 Mod AV0xxFO Mod AV0xxFO FR 8 7 Installation and maintenence must be carried out only by qualified technicians ADJUSTMENT OF GAS FLOW With the model FR is possible to set the gas flow The flow setting is done by turning the Regulation shaft Remove...

Page 4: ...which is generally towards the appliance and upstream of the regulation apparatus from 360mbar to 6bar DIMENSIONS mm C 72 72 72 164 164 164 247 247 265 B 68 0 68 0 68 0 154 5 154 5 154 5 185 200 220 A 148 148 148 240 240 253 350 350 385 φ φ φ φ φ DN15 1 2 DN20 3 4 DN25 1 DN32 1 1 4 DN40 1 1 2 DN50 2 DN65 DN80 DN100 Connection Horizontal position Vertical position Overturned position The manufactur...

Reviews: