11
10
Replace the ceramic
honeycomb filter
WARNING
Danger of fatal electric shock
Water can flow into the device
when it is moved without a
removal limiter (safety line).
▶ Do not cut or damage the line
of the removal limiter.
▶ Do not manipulate or remove
the removal limiter.
CAUTION
Possible health hazard
Impurities in the filter could lead to
contamination of the breathing air.
▶ Replace the filter annually.
The ceramic honeycomb filter is
located on the right rear side of the
device below a cover. It is fastened
with 2 catch springs.
Prerequisite
– The status LED lights up green.
1
Remove the device from the base
plate.
2
Turn the device a little in a clockwise
direction until you have access to the
filter cover.
3
Bend the catch springs of the filter
cover slightly downwards and open
the cover.
38
54043197308479499 © 09-2019
967.258.00.0(03)
Clean the spray nozzle
• For cleaning, use a soft, lint-free
cloth.
• Geberit AquaClean cleaning agent
is particularly suitable for all
surfaces of the device.
1
Lift up the WC lid and the WC seat
ring.
2
Press the <+> and <Shower> buttons
at the same time.
✓ The spray arm extends fully.
3
Hold the spray arm firmly and
remove the spray nozzle from the
front to clean and descale it. Always
ensure that the spray nozzle moves
parallel to the spray arm.
4
Replace the spray nozzle if it can no
longer be completely cleaned and
descaled.
5
Spray the spray arm with Geberit
AquaClean cleaning agent. Then
rinse it thoroughly with warm water.
6
Dry the spray nozzle carefully.
7
Mount the spray nozzle.
8
Press the <Shower> button.
✓ The spray arm retracts fully. The
cleaning procedure is now
complete.
54043197308479499 © 09-2019
967.258.00.0(03)
37