Geba Tronic DC2 S Instructions For Assembly And Use Download Page 3

industrial controls

®

industrial controls

®

NC

CC

GND

  

+

Spannungs- versorgung

Steuerlogik

Rohrantrieb

  5 A

Trafo

 

Service

Anzeige

 Funkempfänger 

Antenne

Lerntaste

24 V 

Netz

230V / 50 Hz

10 A

Funktionsleuchte

1
2
3
4

DIP
Schalter

+   -

N

M

 PE PE  N  L1

+   -

Vorendschalter

Externer Taster

  2 A

Sicherheitsleiste 

DW

8,2 k 

NOT-AUS

Lichtschranke

Assembly Instructions

Assembly of the logic unit (inside area):

1. Put the screw-driver into the gap of the enclosure front, push the screw-driver up and 

open the enclosure.

2. Remove the control PCB (which is force fitted to the inside of the enclosure).
3. Locate the screwed glands supplied (sealing nipple left side) in the 

enclosure and replace the PCB. (Please ensure PCB is firmly in position)

4. Bore the fastening holes and fix the enclosure bracket at the wall.
5. Insert the wires through the cable entry (sealing nipple). 

Ensure tight seating of sealing nipple and cable gland, otherwise the water-protection ot 
the appliance cannot be assured.

6. According to connection diagram connect the wires to the corresponding terminals:

Safety edge (Option)

The DC2 ”S“ has the facility for connection of either a pneumatic or an electrical 
safety edge, with no requirement for additional external monitoring/evaluation unit.
If an electrical type safety edge is fitted, the 8,2 k

resistor should be connected to the 

2 electrical contacts at the end of the safety edge.
If a pneumatic version is fitted the resistor should be fitted in series with the normally 
closed contact. Also a pre-limit switch should be installed on the door approximately 
50mm from floor level.

Tubular Motor 

Care should be taken that the 

UP and 

▼ 

DOWN connections from the tubular motor

to the controller are made in the correct orientation .

The connection should be made with the door in the closed or half-closed position.
If on power-up the door moves in the wrong direction, the power should be broken, 
the 

▲ 

and 

connections reversed, and then the controller should function correctly.

Wiring diagram DC2 ”S“

antenna

DIP-
SWITCH

transformer

radio-receiver

control-light

safety edge

pre-limit-switch

photo-cell

external key-switch

learning push key

tubular drive

power supply
230V / 50 Hz

STOP
button

Attention!

Only a qualified electrician
should make the final power
supply connections!

Service 
indicator

Reviews: