background image

The modified lock-out time is saved!

Program 5
Changing the control time - lock-out time

= dynamic*

= static*

*Lock-out time:

 dynamic

 = The lock-out time is extended by 10 sec. with                                     

                    every wrong entry (max. 255 sec.)

static

 = The lock-out time is according the set time( 000 = turned off)           

Enter 3 digit 

time 001-255

button

push

push

button

button

button

push

push

button

push

push

button

push

button

push

button

Program 2
Creating a new pass code

Factory setting = 1- 4

The new pass code is now saved!

You can enter up to 50 different pass on the memories 00-49!

sound signal

2x long

Enter 8 digit

mastercode

Enter 2 digit 

memory slot,

e.g. 07 or 28

Enter 4 or 5

digit pass code

sound signal

1x long

The entered pass code is now stored in the selected memory slot ! 

Enter 8 digit

mastercode

sound signal

2x long

sound signal

1x long

sound signal

1x long

Keypad

Keypad

Summary of Contents for Cody Universal 2

Page 1: ...5 V1 0 Cody Universal 2 GB Assembly connection and maintenance of the device may only be executed by personnel trained accordingly At this the underlying national and local regulations have to be obse...

Page 2: ...the company with the master code 12345678 Pass code The pass code is either a four or five digit numeral code by which you operate your door drive unit You have the possibility to store up to 50 diff...

Page 3: ...ach other so it is not possible that both relays can be switched at the same time After expiration of the of 60 seconds the Cody Universal 2 locks automatically This function however can be interrupte...

Page 4: ...therwise the water protection ot the appliance cannot be assured 6 According to connection diagram connect the wires to the corresponding terminals Transponder Program 2 Deleting transponder keys Dele...

Page 5: ...nted directly on metal Then use a spacer case No 508 000G 00 Program 1 Teach in of transponder keys Put the desired key to the reader LED flashes 1x long Technical Data Supply voltage 230 240 V AC Out...

Page 6: ...de to your personal code of choice Enter 8 digit mastercode The new mastercode is now saved Program 6 Entering a pass code Keypad Enter 4 or 5 digit pass code button push button push push button A cor...

Page 7: ...tton button push push button push push button push button push button Program 2 Creating a new pass code Factory setting 1 4 The new pass code is now saved You can enter up to 50 different pass on the...

Page 8: ...button push button Enter 3 digit time 001 255 Program 3 Deleting a pass code push button push button push button push button Enter of 2 digit memory slot e g 07 or 28 sound signal 2x long Enter 8 dig...

Reviews: