INSTALLATION INSTRUCTIONS

PREPARE THE INSTALLATION LOCATION

Omit Step 1 if the hood will be installed under
cabinets with flush bottom.

1. 

Attach a wood filler strip at each side of the 
recessed area under the cabinets. Use two
2.5 cm x 5 cm (1

x 2

) strips cut to length. If 

the recess is deeper than 2.5 cm (1

), use thicker 

strips. Attach strips with 3.2 cm (1

1

4

) wood 

screws, 7.6 cm (3

) from each end of the strip.

2. 

Measure and mark the electrical wiring 
opening in the wall or cabinet.

WARNING: When cutting or drilling into
the wall or a cabinet, be careful not to cut
existing electrical wiring.

3. 

Use 3.2 cm (1

1

4

) bit to drill the opening for 

the electrical wiring.

4.

Center the hood in the installation opening 

and trace the keyhole slots onto the wood 
filler strips on the cabinet bottom.

5.

Screw four #10 x 7/8 wood screws into the exact 

center of the narrow end of the traced keyhole 
slots. Allow 9 mm (3/8

) of the screws to project, 

so that the hood can be fitted into place later.

1.9 cm = 3/4

3.5 cm = 1

1

2

19 cm = 7

1

2

25 cm = 9

7

8

26.7 cm = 10

1

2

30 cm = 12

35.4 cm = 13

15

16

76.2 cm = 30

TOOLS AND MATERIALS REQUIRED

❑ 

Drill and 2 bits; 3 mm (1/8

) and 3.2 cm (1

1

4

❑ 

Straight blade and Phillips head screwdriver

❑ 

Pliers

❑ 

Pencil and ruler and/or tape measure

❑ 

Saber saw or keyhole saw

❑ 

Electrical wiring and supplies of type to 
comply with local codes

The following materials are required only for
installations on recessed bottom kitchen
cabinets (purchase locally):

❑ 

Two 2.5 cm x 5 cm x 30 cm (1

x 2

x 12

(approximate length) wood strips

❑ 

Four 3.2 cm (1

1

4

) long flat head screws

PREPARE THE HOOD

1. 

Unpack the hood. Included is 1 Ductfree 
Microtek

®

System I Filter.

2.

Remove the wiring box cover. A plastic bag 

containing loose mounting hardware is under 
the cover.

3. 

Remove the top or rear electrical knockout.

Ductfree filter

(3

)

(3

)

7.6 cm

7.6 cm

For installation on
recessed bottom
cabinets only.

Wiring
box cover

Keyhole slots

Summary of Contents for JN319

Page 1: ...ational Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Use with approved cord connection kit only This unit must be grounded WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Keep f...

Page 2: ... lubricated and never needs oiling Fan Assembly Light Bulb Replacement Remove the filter Remove the two screws holding the motor bracket to the range hood and unplug the fan assembly Be careful not to allow the fan assembly to drop when the screws are removed The light bulb not supplied with the hood should be 75 watts maximum Remove the light lens covering the bulb by pressing the two extending t...

Page 3: ... the narrow end of the traced keyhole slots Allow 9 mm 3 8 of the screws to project so that the hood can be fitted into place later 1 9 cm 3 4 3 5 cm 11 2 19 cm 71 2 25 cm 97 8 26 7 cm 101 2 30 cm 12 35 4 cm 1315 16 76 2 cm 30 TOOLS AND MATERIALS REQUIRED Drill and 2 bits 3 mm 1 8 and 3 2 cm 11 4 Straight blade and Phillips head screwdriver Pliers Pencil and ruler and or tape measure Saber saw or ...

Page 4: ...hrough the hole drilled in the wall or cabinet Split wiring for 15 2 cm 6 and install the proper connector for the type of wire used 2 Position the hood so that a The wiring is routed through the knockout opening b The large part of the keyhole slots fit over the hood mounting screws 3 Adjust the hood so that the front is flush with the cabinet frame 4 Tighten the hood mounting screws firmly 5 Fas...