Electrical Specifications
Wire Size and Breaker Size
Warning:
All wiring, including installation of the receptacle, must be in accordance with the National
Electric Code, local codes, ordinances, and regulations.
•
Use only the wiring size recommended for single outlet branch circuit.
•
Use only the type and size fuse of HACR circuit breaker indicated on the unit’s rating plate. Proper
current protection is the responsibility of the owner.
Recommended branch circuit wire sizes*
Nameplate
AWG Wire
maximum circuit
size**
breaker size
15A
14
20A
12
30A
10
AWG—American Wire Gauge
* Single circuit breaker from main box
** Based on copper wire, single insulated conductor at 60° C
Note:
Use copper conductors only.
Power Supply Kits
Tandem
15 Amp.
Perpendicular
20 Amp.
Large Tandem
30 Amp.
265/230/208 Volt
Power
Supply Kits
Wall Plug
Configuration
Circuit Protective Device
Heater Wattage
@ 230/208 volts
RAK3152
RAK3202
RAK3302
RAK5157
RAK5207
RAK5307
Tandem
Perpendicular
Large Tandem
Direct Connect
Direct Connect
Direct Connect
15 Amp time Delay Fuse or Breaker
20 Amp time Delay Fuse or Breaker
30 Amp time Delay Fuse or Breaker
15 Amp time Delay Fuse or Breaker
20 Amp time Delay Fuse or Breaker
30 Amp time Delay Fuse or Breaker
2.55/2.09 KW
3.45/2.82 KW
5.00/4.10 KW
2.55 KW
3.45 KW
5.00 KW