Fig.17
Prerequisite:
•
The pneumatic and electrical connections on the plant side can remain on the
control top.
Notice
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
► Protect the permanent magnet against impact stress.
Carry out the following steps:
1.
Remove the clamps (R) between control top and actuator.
2.
Pull off the control top (B) upwards.
3.
Release the T.VIS switch bar (1) by applying a hex key at (1.1) or an a/f 13
open end wrench at (1.2) and remove it.
®
The control top has been taken off.
10.5.3 Disconnecting the Valve from the Housing
Maintenance
Disassembling Valve N
430BAL008302EN_10
16.03.2023
43