Requirement:
•
Use only the exhaust air throttle (75) and sound absorber (26) specified in the
spare parts list, see Chapter 13, Page 58.
Carry out the following steps:
1.
Check that the control air can exit freely from the sound absorber (26), reflux
valve (26.1), filter (5.1) and exhaust air throttle (75) and replace the parts if
necessary.
!
The non-return valve (26.1) cannot be replaced.
2.
Do not grease the spare parts before fitting them.
®