10.3
Removing the Control Top from the Valve
Fig.29
Requirement:
•
Make sure that the solenoid valve is not actuated.
Hint!
The pneumatic and electrical connections can remain on the control
top.
Carry out the following steps:
1.
Release the screw connection (39) and remove the clamp ring (15).
2.
Pull the control top vertically off the valve.
®
Light-emitting diode A (green) will go out and light-emitting diode B will
flash yellow.
®
Done
10.4
Dismantling the Control Top into its Components
10.4.1 Removing the Cap
Fig.30
Maintenance
Removing the Control Top from the Valve