Installing double mechanical seal
Coat tie bolts (0905.01) with Loctite type 243 and
screw in hand-tight (!) into the bearing housings or
motor stool.
Fig.75
Insert the O-ring (0412.01) into the seal cartridge
(0491.00).
Fig.76
Press the seal cartridge (0491.00) into the seat of
the discharge casing (0107.00).
Fig.77:
Discharge casing with seal
cartridge
Connect the seal cartridge (0491.00) with the
discharge casing (0107.00)
GEA Hilge CONTRA I: Fastening from the front
with countersunk screws (1000.03) Torque: 1.5 - 2
Nm
GEA Hilge CONTRA II: Fastening from the rear
with hex socket screws (0914.02), washer
(0554.03).
torque: 8 Nm
Fig.78
Malfunctions / repairs
Repair
BA.10A.ADY.001.GB_1
78
20.07.2018