Installing single conical spring mechanical seal
Push the rotating unit of the mechanical seal
(0433.00) and installation sleeve in the assembled
state as far as it will go onto the connection
(0211.00).
Fig.69:
Rotating unit of the
mechanical seal
Push seal spacer (0577.00) on the shaft (0211.00).
Fig.70:
Seal spacer
→ The single conical spring mechanical seal has been installed.