![GEA ECOVENT TEFASEP-Gold ECO E Assembling Instruction Download Page 9](http://html1.mh-extra.com/html/gea/ecovent-tefasep-gold-eco-e/ecovent-tefasep-gold-eco-e_assembling-instruction_4024216009.webp)
4
Tefasep Gold
4.1
Note
Hint!
TEFASEP gold valve seat seals achieve optimal sealing only after an initial CIP or SIP
cleaning.
CIP or SIP cleaning operating conditions:
-Medium: lye, hot water or saturated steam
- Temperature: >80 °C (176 °F)
- Hold time: 20 … 30 min
The valve must be brought to the closed position for a brief period (3 minutes)
immediately after CIP or SIP cleaning.
During commissioning, regularly check all sealing points for leaks.
Exchange defective seals and repeat the CIP or SIP process.
Tefasep Gold
Note
221BAL015386EN_1
01.11.2023
9