Installation and Commissioning
Valve with Detachable Pipe Connection Elements
24
Operating Instructions · ECOVENT
®
Valve N/W and N.M DN 10/15
Edition 2014-07-04
Installation and Commissioning
Notes on Installation
The valve can be installed in any position. However, care must be taken to ensure that
the valve housing and the pipe system can drain properly.
To prevent damage, make sure that
•
the valve is installed in the pipe system free of tension and
•
no foreign materials (e.g. tools, bolts, lubricants) are left in the system.
Valve with Detachable Pipe Connection Elements
This section describes the procedure to fit the valve.
CAUTION
Liquids in pipes
Danger of injury due to liquid spraying out
Therefore, before releasing any pipe connections or hinged clamps: drain the pipe
and, if necessary, clean or rinse it.
Separate the pipe section in which the valve is to be fitted from the rest of the piping
system to prevent product entering again.
Carry out the following steps:
Fit valves with detachable pipe connection elements – using suitable connection
fittings – directly into the pipe system.
Done.