2.
Actuate the valve with compressed air.
If provided, set the proximity switch for the actuated position. For reference
regarding the stroke to be expected see the “Valve Stroke“ table
Section 10.14.2, Page 59.
®
The feedback unit has been set.
Hint!
If a control head is installed, the specifications of the respective
operating instructions must be observed.
10.14.2 Valve Stroke
Strokes Depending on Size
Size DN
Size OD
Valve stroke [mm]
DN 15
OD 3/4"
6
DN 25
OD 1"
10
DN 40
OD 1 1/2"
12.5
DN 50
OD 2"
25
DN 65
OD 2 1/2"
25
DN 80
OD 3"
25
DN 100
OD 4"
25
Maintenance
430BAL012727EN_1
03.01.2018
59