Air requirement for opening the actuators LL
Nominal width of valve
Actuator
Reference
stroke
Air
Requirement
DN
OD
[mm]
[dm
3
]
DN 15
OD 3/4"
PA30 LL
6
0.1
DN 25
OD 1"
PA30 LL
10
0.1
DN 40
OD 1 1/2"
PA40 LL
12.5
0.2
DN 50
OD 2"
PA50 LL
25
0.5
DN 65
OD 2 1/2"
PA80 LL
25
1.3
DN 80
OD 3"
PA80 LL
25
1.3
DN 100
OD 4"
PA100 LL
25
2.2
Air requirement for closing the actuators LL
Nominal width of valve
Actuator
Air Requirement
DN
OD
[dm
3
]
DN 15
OD 3/4"
PA30 LL
0.1
DN 25
OD 1"
PA30 LL
0.1
DN 40
OD 1 1/2"
PA40 LL
0.3
DN 50
OD 2"
PA50 LL
0.5
DN 65
OD 2 1/2"
PA80 LL
2.9
DN 80
OD 3"
PA80 LL
2.9
DN 100
OD 4"
PA100 LL
7.0
6.4.2
Establishing the Compressed Air Supply
A prerequisite for the reliable operation of the valve is that the compressed air
hoses are cut exactly square.
Tools required:
•
A hose cutter
Carry out the following steps:
1.
Depressurize the pneumatic connection at the place where you are working.
2.
Use the hose cutter to cut the pneumatic hoses square.
3.
Connect a hose to the valve.
®
The compressed air supply has been established.
Assembly and installation