Fig.36:
Lifting out the lifting piston
®
Actuator PA35 PV is disassembled.
10.10.2 Assembling actuator PA35 PV
Hint!
Pay attention to the following points when assembling the actuator:
•
Replace all visible seals.
•
Thoroughly clean and check the interior cylinder contact surfaces, O-ring
grooves, piston rod and piston disc.
•
When changing the seals, do not damage the seal groove.
•
Use only replacement seals from the seal set indicated in the list of
spare parts.
•
Grease all seals and the associated contact surfaces with the food-
grade lubricant PARALIQ GTE 703.
Tools required:
•
Hex socket key
•
Assembly tool for PA35
•
Food-grade lubricant PARALIQ GTE 703
Carry out the following steps:
1.
Assemble the actuator in the reverse order of disassembly, see
Section 10.10.1, Page 44.
!
Anti-twist device: when inserting the actuator components into the actuator
cylinder, the cross pin of the piston rod must be positioned in the recess
inside the cylinder.
!
After placement of the actuator cover and the retaining ring, tighten the
assembly tool again so that the actuator cover is pressed upwards. Then
screw the retaining ring hand-tight to the actuator cover using the hex socket
screws.
®
Actuator PA35 PV is assembled.
Maintenance
Disassembling and assembling actuator PA35 PV
430BAL013317EN_1
48
11.03.2019
Summary of Contents for Aseptomag AMV
Page 60: ......