![GEA Bock HG12P/110-4 Assembly Instructions Manual Download Page 12](http://html1.mh-extra.com/html/gea-bock/hg12p-110-4/hg12p-110-4_assembly-instructions-manual_572325012.webp)
12
D
GB
F
E
I
Ru
09652-06.2015-DGbFEIRu
4
|
Compressor assembly
Pipe connection
Pipe connection
4.7 Operating mode of the lockable service connections
Fig. 18
Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.
Fig. 19
Opening the service connection
Spindle: Turn ½ - 1 turn to the right clockwise.
—> Service connection opened / shut-off valve opened.
Service connec
-
tion closed
Connection
blocked
Spindle
Service connec
-
tion opened
Spindle
Connection
open
Compressor
Compressor
Before opening or closing the shut-off valve, release the valve spindle seal by approx. ¼ of a turn
counter-clockwise.
After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.
Fig. 16
Fig. 17
4.6 Operating the shut-off valves
Valve spindle seal
Release
Tighten