background image

2 C

  

CUTOUT FOR INSTALLATION OVER A 
WARMING DRAWER

NOTE: 

Install the oven only with specific models listed on the label located on top of the oven.

NOTE: 

Additional clearances between cutouts may be required. Check to be sure the oven 

supports above the Warming Drawer location do not obstruct the required interior depth and height.

When installing a Warming Drawer below a single, double, or combination oven, a separate 
120V, 60 HZ, properly grounded receptacle must be installed. Refer to installation instructions 
packed with the Warming Drawer for specific installation requirements.

Anti-Tip Block Against 

Rear Wall Per Warming 

Drawer Requirement

2" (5.1 cm) 

Min. 

Per Warming 

Drawer 

Requirement

Continue to Section 3 for Double Wall Oven with Pedestal. Otherwise, continue to Section 4.

3 A

  

DETERMINING WHEN TO USE THE PEDESTAL 
(30” DOUBLE OVENS ONLY)

WHEN TO USE THE PEDESTAL

When replacing an older GE Appliances 30” double wall oven with a new GE Appliances model. 
Cutout height = 51-13/16” to 51-15/16”. This is our traditional cutout height.

WHEN NOT TO USE THE PEDESTAL

When replacing a 30” double wall oven from another manufacturer (ie. Whirlpool) with a new 
GE Appliances 30” double wall oven. Cutout height = 50-1/4”. You will need to verify that the 
existing cutout matches the 50-1/4” dimension.

If the new GE Appliances 30” double wall oven is being installed into new construction (ie. not a 
replacement), then the recommended installation is to use the Pedestal.

3 B

  

PEDESTAL RAIL INSTALLATION 
(30” DOUBLE OVENS ONLY)

A. 

 Position the pedestal rails with the top cutout toward the front of the opening and the flanges 
on the bottom, pointing toward the center.  Locate each rail on the floor or cabinet runner, 
slightly inward from the side of the cabinet.  Make sure the front of each rail is not protruding 
beyond the front of the cabinet opening.

B.

  Drill pilot holes and attach rails to runner or bottom of cabinet with provided hardware.

31-2000923 Rev. 1   11-21   GEA

Flanges toward 
center of cutout

Top cutout 
toward front

Attachment 
screws

Summary of Contents for ZTDX1DSSN

Page 1: ...so remove plastic on trims and panel all tape around the oven and any shipping screws securing the oven to the base pad Open oven door and remove literature pack and oven racks Remove the bottom trim...

Page 2: ...observe all dimensions and requirements Cutout observe all dimensions and requirements 2 5 1 cm Min 30 5 77 5 cm 30 models Center Line Center Line Side by Side Installations Install two ovens in sepa...

Page 3: ...double wall oven with a new GE Appliances model Cutout height 51 13 16 to 51 15 16 This is our traditional cutout height WHEN NOT TO USE THE PEDESTAL When replacing a 30 double wall oven from another...

Page 4: ...cal system If you connect to aluminum wiring properly installed connectors approved for use with aluminum wiring must be used Effective January 1 1996 the National Electrical Code requires that new co...

Page 5: ...as a grip Carefully push against oven front frame Do not push against outside edges C As you slide the oven back pull the string so that the conduit will lie on top of the oven in a natural loop For...

Page 6: ...mm From the Front of the Cutout Metal Posts to be installed in the rear of cavity Oven rack guide shown in place 11 BOTTOM TRIM INSTALLATION With oven installed attach the bottom trim through its mou...

Page 7: ...ice to the building Check that all packing material and tape have been removed Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfa...

Page 8: ......

Page 9: ...rno y los tornillos de env o que fijan el horno a la almohadilla base Abra la puerta del horno y quite el material informativo y las bandejas del horno Quite el reborde inferior de la parte superior d...

Page 10: ...erales 11 16 1 75 cm 11 16 1 75 cm E Espacio respecto de esquinas adyacentes cajones paredes etc cuando la puerta est abierta 23 53 3 cm min 23 53 3 cm min F Espacio desde la abertura parte superior 1...

Page 11: ...piso o la corredera del gabinete levemente hacia dentro desde el costado del gabinete Aseg rese de que el frente de cada riel no sobresalga m s all del frente de la abertura del gabinete B Realice ag...

Page 12: ...sted debe usar un sistema el ctrico de fase nica de 120 208 VAC o 120 240 VAC de 60 hercios Si tiene una conexi n con cableado de aluminio deben utilizarse conectores adecuadamente instalados para uti...

Page 13: ...tubo de la estufa se ajusta en la caja Tapa de la caja de conexiones 8 CONEXI N DE CIRCUITO DERIVADO DE CUATRO CONDUCTORES NOTA Si los cables dom sticos son conductores de aluminio ver la ADVERTENCIA...

Page 14: ...orde inferior a trav s de sus agujeros de montaje frente al soporte vertical utilizando los dos tornillos con cabeza recortada provistos El labio de la cubierta inferior deber ser ubicado debajo de la...

Page 15: ...se haya quitado todo el material de empaque y la cinta adhesiva No quitar estos materiales puede provocar da os al electrodom stico una vez que el aparato se haya encendido y las superficies se hayan...

Page 16: ......