Installation Preparation
INST
ALLA
TION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT –
Save these
instructions for local inspector’s use.
•
IMPORTANT –
Observe all
governing codes and ordinances.
•
Note to Installer –
Be sure to leave these
instructions with the owner.
•
Note to Owner –
Keep these instructions for
future reference.
•
Proper installation is the responsibility of the
installer.
•
Product failure due to improper installation is not
covered under the Warranty.
•
You must use all supplied parts and use proper
installation procedures as described in these
instructions when installing this air conditioner.
Questions? Call 844-GE4-PTAC (or 844-434-7822 ) or
Visit our Website at:
GEAppliances.com
IMPORTANT ELECTRICAL
SAFETY—READ CAREFULLY
• All electrical connections and wiring MUST
be installed by a qualified electrician.
• Follow the National Electrical Code (NEC) and local
codes and ordinances.
• For personal safety, this Zoneline must be properly
grounded.
• Protective devices (fuses or circuit breakers)
acceptable for Zoneline installations are specified
on the nameplate of each unit.
• Do not use an extension cord with this unit.
• Aluminum building wiring may present special
problems—consult a qualified electrician.
• When the unit is not running there is still voltage to
the electrical controls.
• Disconnect the power to the unit before servicing
by removing the branch circuit fuses or turning the
circuit breakers off at the panel.
WARNING
ELECTRICAL
REQUIREMENTS
Wire Size
Use
ONLY
wire size recommended for
single outlet branch circuit
Fuse/Circuit
Breaker
User ONLY type and size fuse or
HACR circuit breaker indicted on units
rating plate. Proper over current pro-
tection to the units is the responsibilty
of the owner.
Grounding
8QLW0867EHJURXQGHGIURPEUDQFK
circuit to unit, or through separate
ground wire provided on permanently
connected units. Be sure that branch
circuit is grounded.
Wire Sizing
Use recommended wire size given in
tables and install a single branch cir-
cuit. All wiring must comply with local
and national codes.
NOTE: Use copper conductors only.
NOTE: All field wiring must comply with NEC and
local codes. It is the responsibility of the installer
to insure that the electrical codes are met.
• Use ONLY the wiring size recommended for single
outlet branch circuit.
• Proper current protection is the responsibility of the
owner.
Recommended branch circuit wire sizes*
Nameplate
maximum circuit
breaker size
AWG Wire size**
$
$
$
AWG – American Wire Gauge
6LQJOHFLUFXLWEUHDNHUIURPPDLQER[
%DVHGRQ¶RUOHVVRIFRSSHUZLUHVLQJOHLQVXODWHGFRQGXFWRU
DW&:LUHVL]HVDUHSHU1(&
NOTE:
Use copper conductors only.