Auxiliary 

Additional controls are located
behind the room cabinet.

To remove the room cabinet,
see page 5.

VENT

OPEN

— TEMP OVERRIDE —

SETBACK 

 

FAN

CYCLE 

 

\

— 

TEMP 

TL2 TL1

 I I 

‘EAT 

TL2 TL1

 

 

 

 

\

, Temp Override 

Set this switch at FREEZE
SENTINEL and whenever the
room air temperature at the air
conditioner falls to approximately

 the unit will automatically

come on in the heating mode,
regardless of whether the 
switch has turned the air
conditioner off.

Set this switch at SET BACK and

the same thing occurs whenever the
room air temperature at the air
conditioner 

 to approximately

The UNIT POWER switch must be
at ON for the TEMP 
to operate.

CLOSE

Ventilation Control

Unit Power’Switch

 knob is set at CLOSE at the

This switch is set at ON at the

factory. When it is in this position,

factory to allow the air conditioner

controls are set at NORMAL at

the vent door is closed and only

indoor air is filtered, cooled or

heated and circulated by the air
conditioner.

Switching the knob to OPEN opens

the vent door to allow some outside
air to enter the room. However,
cooling or heating effectiveness is
reduced when the control is set at
OPEN, so we suggest you don’t
keep it there long.

If the knob is not set 

 the way in

the CLOSE position, the vent light
will remain on.

to operate in the cool, heat or fan
only modes and the Freeze Sentinel
to operate if it is needed.

If this switch is set at OFF, the air
conditioner will not operate in any
mode and the Freeze Sentinel will
not function.

Caution: The Unit Power Switch
is not a power disconnect.  
If 
power must be disconnected from
the unit, remove the line cord plug
from the wall outlet, or remove the
fuses, or turn off the circuit
breakers at the power panel.

 Cycle 

The Fan Cycle Switch is set at
CONTINUOUS at the factory to
provide continuous fan operation in
cool or heat modes. If you want the
fan to cycle on and off with the

\

compressor or heater, set the
switch at 

Temp Limit 

The TEMP LIMIT switch is used
to adjust the thermostat range. Set
it to limit the lowest temperature
that can be obtained on cooling and
the highest temperature that can be
obtained on heating.

COOL and HEAT settings range
from NORMAL to 

 Both

the factory.

Temperature Limit Ranges

(approximate)

Cooling

Heating

Normal

57-90°

57-90°

TL1

71-90°

57-77°

TL2

77-90°

57-73°

TL3

83-90°

57-68°

4

Summary of Contents for Zoneline 2500

Page 1: ...nergy Saving Tips 2 Fan Cycle Switch 4 Freeze Sentinel 3 4 Indicator Lights 3 Master Controls 3 Model and Serial Numbers 2 Problem Solver 6 Repair Service 7 Room Cabinet and Case 5 Safety Instructions 2 Thermostat Control 3 Unit Power Switch 4 Ventilation Control 4 Warranty Back Cover Heat Cool tineline Model 2500 Seties ...

Page 2: ...p ance When using this appliance always exercise basic safety precautions including the following Use this app ance ordy for its intended purpose as described in this Use and Care Book c This air conditioner must be properly insblled in accordance with the Ins llation Instructions before it is used Never use an extension cord with this appliance SAW THESE STRUCTIONS Energy Saving mps Keep the air ...

Page 3: ...mode ON STOP II I OPERATION PUSH COOL HEAT II HIGH LOW ANSPEED Master Controls Push the Operation Button once to turn the air conditioner on push again to turn it off If the unit does not operate when you push this button to start it check to see if the Unit Power Switch located behind the room cabinet is on See page 47 Slide the Selector Switch to COOL for cooling or to HEAT for heating Slide the...

Page 4: ...tside air to enter the room However cooling or heating effectiveness is reduced when the control is set at OPEN so we suggest you don t keep it there long If the knob is not set all the way in the CLOSE position the vent light will remain on to operate in the cool heat or fan only modes and the Freeze Sentinel to operate if it is needed If this switch is set at OFF the air conditioner will not ope...

Page 5: ...ides lift up and pull forward To remove the air filter grasp the pull tabs on the front of the filter as shown and pull toward you until the three tabs at the top and bottom of the filter come out of the slots in the chassis Vacuum the falter on the dirty side or wash it with running water Run water through from the cleaner side of the filter to drive out accumulated dust and lint Shake to dry Not...

Page 6: ...n Allow time for it to cool down or warm up Condition air maybe escaping through open furnace floor registers and cold air returns o Ventilation Control may set at OPEN psition allowing outside air to enter the room o The Tem mture Lifit Switch may be set at a setting other than normal This will limit the operating ranges See page 4 Position of the louvers wH1 affect temperature Seepage 3 Dust acc...

Page 7: ...urther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations GE Appliances Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel 20...

Page 8: ...AT IS N COVERED Service trips to teach you how to Improper installation Failure of the product resulting from use the product If you have an installation modifications to the product or due to Read your Use and Cam material problem or if the air conditioner unreasonable use including failure to If you then have any questions is of improper cooling or heating provide reasonable and necessary about ...

Reviews: