GE ZISB420DH Manual Download Page 10

STANDARD INSTALLATION

DISPENSER TRIM

RAISED OVERLAY PANEL DESIGN ON DISPENSER MODELS

1/4" PANEL DISPENSER TRIM

3/4" OVERLAY PANEL DISPENSER TRIM

Freezer Door

1/4" Framed Panel

Ice/Water Dispenser

1/4"

Total

Thickness

Freezer Door

1/4" Backer Panel

.10" Spacer Panel

3/4" Overlay Panel

Ice/Water Dispenser

1.10"

Total

Thickness

A

B

16 3/4"

10 5/8"

1/4" Backer Panel

 

3/4" Overlay Panel

.10" Spacer

1.10”

Total

Thickness

D

C

DISPENSER TRIM

SIDE VIEW CROSS SECTION

(Showing Raised Overlay  

with Middle Rail)

NOTES

These refrigerators are supplied with two 

dispenser trims, one for framed panels 

and one for overlay panels.

1/4" Panel Dispenser Trim: 
The framed panel must be 1/4” nominal 
thickness to fit the dispenser trim.

•  The dispenser trim fits over the custom 

panel and snaps into the freezer door.

•  If the panel is less than 0.250" thick, a 

noticeable gap may be created around 
the dispenser trim. Foam tape may be 
applied on the door to improve the fit.

•  If the panel is more than 0.250" thick,  

the dispenser trim cannot be secured  
to the door.

3/4" Overlay Panel Dispenser Trim: 
The 3/4” overlay dispenser trim is 
designed to fit a total panel thickness of 
1.100".

 •  If the panel is less than 1.100" thick, a 

noticeable gap may be created around 
the dispenser trim.

•  If the panel is more than 1.100" thick, 

the dispenser trim cannot be secured to 
the door.

•  The overlay panel must be constructed 

according to the specifications shown to 
achieve the correct total thickness.

•   Alternative panel construction methods 

such as securing a 3/4" panel to a 1/4" 
backer panel cannot be used. Another 
method, routing a 3/4"-thick panel 
on all sides, cannot be used. These 
methods will not result in the required 
1.100" panel thickness.

•  When a raised panel design is to be 

used, a custom middle rail is required.

Raised Overlay Panel Design on  

Dispenser Models: 
When a raised panel design is to be used, 
a custom wide middle rail is required to 
accept the dispenser trim.

•  The middle rail must be wide enough to 

allow for the dispenser trim to overlap 
the opening.

•  The middle rail must be 1.10” total 

thickness to accept the dispenser trim.

Product Specification Revised 10/14

ZISB420DH

GE Monogram

®

 42" Built-In Side-by-Side Refrigerator

Summary of Contents for ZISB420DH

Page 1: ...SECTION 1 Product Specification Revised 10 14 ZISB420DH GE Monogram 42 Built In Side by Side Refrigerator SECTION 2 1 4 FRAMED PANELS 3 4 OVERLAY PANELS FLUSH INSET INSTALLATION STANDARD INSTALLATION ...

Page 2: ...ssed into the back wall 44 111 8 83 1 2 212 1 72 3 16 183 4 68 13 16 174 8 ZISB420DH FRONT VIEW 11 5 16 28 7 20 5 8 52 4 25 7 8 65 7 3 3 8 8 6 3 7 6 SIDE VIEW 83 1 2 212 1 13 1 2 34 3 40 101 6 These refrigerators are equipped with a 2 position door stop The factory set 115 door swing can be adjusted to 90 if clearances to adjacent cabinets or walls is restricted Allow a 15 minimum clearance to wal...

Page 3: ...detailed instructions NOTES FLUSH INSET INSTALLATION 3 4 PANELS FLUSH INSET INSTALLATION FLUSH INSTALLATION ZISB420DH 45 114 3 Flush inset width 43 1 2 110 5 Width between cleats 7 17 8 7 17 8 3 4 1 9 Width of side cleats 5 1 4 13 3 1 2 1 3 26 3 16 66 5 Flush inset depth 20 15 16 53 2 Depth to cleat FRONT VIEW SIDE VIEW TOP VIEW WATER 3 1 2 8 9 W Finished cleats Finished cleats Case Trim 3 4 Panel...

Page 4: ... panel weight Fresh food door panels 75 lbs Freezer drawer panel 53 lbs Grille panel 18 lbs Door Handles Door handle not included A custom handle supplied by your cabinet maker may be used ZKHPSS1 Professional tubular stainless steel handle designed to fit 3 4 panels Kit includes one handle 30 1 2 long ZKHSS2 European tubular stainless steel handle designed to fit 3 4 panels Kit includes one handl...

Page 5: ...cured to the door The overlay panel must be constructed according to the specifications shown to achieve the correct total thickness When a raised panel design is to be used a custom middle rail is required Raised Panel Design on Dispenser Models When a raised panel design is to be used a custom wide middle rail is required to accept the dispenser trim B The middle rail must be wide enough to allo...

Page 6: ...wall for 90 door swing These refrigerators are equipped with a 2 position door stop The factory set 130 door swing can be adjusted to 90 if clearances to adjacent cabinets or walls is restricted Allow full 130 door swings for pan removal If the 90 door stop position is used pan access is maintained but pan removal is restricted Allow 13 33 0 min clearance for 130 door swing Allow 19 48 3 min clear...

Page 7: ... top heavy and must be secured to prevent the possibility of tipping forward Failure to do so may result in death or serious injury The information below is for cabinet design only When installing the anti tip system you must use the product installation instructions Determine your installation construction and required anti tip configuration C Installed Under Soffit After installing unit into ins...

Page 8: ...IRP360NXLH_ZIRP360NXRH_ZIRS360NXLH_ZIRS360NXRH NOTES STANDARD INSTALLATION F Side panels must be used whenever the sides of the refrigerator will be exposed The 1 4 side panels will slip into the side case trim Secure the panels to the refrigerator with stick on hook and loop fastener strips Order the side panels from the cabinet manufacturer Product Specification Revised 10 14 ZISB420DH GE Monogr...

Page 9: ...d custom door and grille panels are required 1 4 Framed Panels Order trim kit ZTK42SSH for 1 4 thick custom panels ordered from your cabinet maker The decorative panels slide into the trim Maximum total panel weight Fresh food door panel 75 lbs Freezer drawer panel 53 lbs Grille panel 18 lbs STANDARD INSTALLATION PANEL ASSEMBLY CROSS SECTION Door 1 4 Backer Panel 10 Spacer Panel Supplied Handles T...

Page 10: ...rim cannot be secured to the door 3 4 Overlay Panel Dispenser Trim The 3 4 overlay dispenser trim is designed to fit a total panel thickness of 1 100 If the panel is less than 1 100 thick a noticeable gap may be created around the dispenser trim If the panel is more than 1 100 thick the dispenser trim cannot be secured to the door The overlay panel must be constructed according to the specificatio...

Page 11: ...ect specific temperatures for perishable foods Dispenser with Proximity Sensor Designed to accommodate glassware of all sizes from pitchers to tumblers control graphics light up as you approach and automatically switch off when you walk away Dairy Bin with Center Divider Has a unique magnetic seal that locks in freshness Filter Change Indicator Light Located on the upfront control panel provides a...