– 52 –
T e s t
Mode
Press
Displays
Exit
t01
Start/
Pause
Display defi nes model id (01-03). Always displays"---" when control
board replaced. Proper model must be set when control board
replaced. Rotate knob until desired selection is displayed (01-03),
then press and hold Start/Pause until beep.
Press Power.
Returns to t01
t02
Start/
Pause
Displays the most recent error code. (E00=none) Repeat pressing
Start/Pause to display up to previous 10 error codes. Press and hold
Start/Pause to clear all error codes. (Will then display E00.)
Press Power.
Returns to t02
t03
Start/
Pause
Displays software revision numbers. Press Start/Pause to alternate
between COD (Control software version), EE (eeprom version), and
InV (Inverter software version).
Press Power.
Returns to t03
t04
Start/
Pause
Displays and tests loops on lighting of LED'S and cycle lights.
Buttons beep when pressed.
Press Power.
Returns to t04
t05
Start/
Pause
Displays P and operates pump for 60 seconds, then returns to t05.
Press Power.
Returns to t05
t06
Start/
Pause
Water level control test. Pump runs and displays E at start (no
water in tub). Press Start/Pause to advance. Water valve begins fi ll.
Displays F when reaches FOAM level. Displays nl when reaches
MAIN level, and briefl y displays oF when reaches overfl ow level,
then pumps water out. Displays E when empty.
Press Power.
Pump runs.
Returns to t06
t07
Start/
Pause
Water heater/thermistor test. (
Note:
Main level switch must be
functional.) Fills with water to main level, then operates heater
for up to 5 minutes. Displays temperature of water, as heated, in
degrees F. After 5 minutes, water pumps out, then returns to t07.
Press Power.
Pump runs.
Returns to t07
t08
Start/
Pause
Water valve test. Displays hOt and pump runs. Fills with hot water.
Maximum level is main level switch setting. Pumps out water and
returns to t08.
Press Power.
Pump runs.
Returns to t08
t09
Start/
Pause
Water valve test. Displays Cld and pump runs. Fills with cold water.
Maximum level is main level switch setting. Pumps out water and
returns to t09.
Press Power.
Pump runs.
Returns to t09
t10
Start/
Pause
Tumble test. Displays tt. Wash basket spins in one direction for 5
seconds, pauses, then spins in the opposite direction for 5 seconds.
Repeats until exit initiated. (
Note:
Beginning direction is random.)
Press Power.
Pump runs.
Returns to t10
t11
Start/
Pause
Spin speed-low spin/high spin test. Display shows rpm. Pump runs,
displays 0, then wash basket ramps to 400 rpm. Press Start/Pause
a second time to ramp to 1000 rpm. (May display 999 or 0 for 1000
rpm.) Then motor is unpowered, displays 0, pump runs, and returns
to t11.
Press Power.
Pump runs.
Returns to t11
t12
Start/
Pause
Dispenser motor/mechanism test. Press Start/Pause to advance.
Displays Pdt and fi lls via prewash compartment. Displays
ddt and fi lls via wash compartment. Displays bdt and fi lls via
bleach compartment. Displays Fdt and fi lls via fabric softener
compartment. (
Note:
If main level reached during test, dispenser
operation stops, pump runs, and returns to t12.)
Press Power.
Pump runs.
Returns to t12
t13
Start/
Pause
EOL test sequence. Not used for service.
Press Power.
Returns to t13
t14
Start/
Pause
Spin speed ramp up test. Display shows rpm. Pump runs, displays
0, then wash basket ramps to 100 rpm, pauses, ramps to 350 rpm,
pauses, then ramps to and holds at 1000 rpm. (May display 999 or
0 for 1000 rpm.)
Press Power.
Pump runs.
Returns to t14