CHAPTER 2: MODBUS COMMUNICATION
MEMORY MAP
UR SERIES – COMMUNICATIONS GUIDE
2-89
2
"
6957
Mechanical Jam Events
0 to 1
---
1
F102
0 (Disabled)
"
6958
Reserved (8 items)
---
---
---
F001
0
Motor Learned Data (Read/Write Setting)
M60
6960
Motor Learned Data Starts to Learn
1 to 5
---
1
F001
1
"
6961
Motor Learned Data Calculation Period
1 to 90
minutes 1
F001
15
"
6962
Reserved
---
---
---
F001
0
Motor Learned Data Actual Values (Read Only)
M60
6963
Motor Learned Data Records Number
0 to 250
---
1
F001
0
"
6964
Motor Learned Data Last Cleared Date
0 to 4294967295
---
---
F050
0
"
6966
Motor Learned Data Acceleration Time
0 to 655.35
s
0.01
F001
0
"
6967
Motor Learned Data Starting Current
0.00 to 40.00
× FLA
0.01
F001
0
"
6968
Motor Learned Data Thermal Capacity
Used
0 to 65535
%
1
F001
0
"
6969
Motor Learned Data Motor Load
0.00 to 40.00
× FLA
0.01
F001
0
"
696A
Motor Learned Data Run Time After Start
0 to 4294967295
hr
1
F050
0
"
696C
Reserved
---
---
---
F001
0
Undervoltage (Read/Write Grouped Setting) (12 Modules)
B90
6AF0
Undervoltage 1 Function
0 to 1
---
1
F102
0 (Disabled)
"
6AF1
Undervoltage 1 VT
0 to 11
---
1
F400
0
"
6AF2
Undervoltage 1 Pickup
0 to 3
pu
0.001 F001
800
"
6AF3
Undervoltage 1 Minimum Voltage
0 to 1
pu
0.001 F001
0
"
6AF4
Undervoltage 1 Pickup Delay
0 to 65.535
s
0.001 F001
0
"
6AF5
Undervoltage 1 Reset Delay
0 to 65.535
s
0.001 F001
0
"
6AF6
Undervoltage 1 Block
0 to 4294967295
---
1
F300
0
"
6AF8
Undervoltage 1 Target
0 to 2
---
1
F109
0 (Self-reset)
"
6AF9
Undervoltage 1 Events
0 to 1
---
1
F102
0 (Disabled)
"
6AFA
Undervoltage 1 Reserved (2 items)
---
---
---
F001
0
"
6AFC
...Repeated for Undervoltage 2
"
6B08
...Repeated for Undervoltage 3
"
6B14
...Repeated for Undervoltage 4
"
6B20
...Repeated for Undervoltage 5
"
6B2C
...Repeated for Undervoltage 6
"
6B38
...Repeated for Undervoltage 7
"
6B44
...Repeated for Undervoltage 8
"
6B50
...Repeated for Undervoltage 9
"
6B5C
...Repeated for Undervoltage 10
"
6B68
...Repeated for Undervoltage 11
"
6B74
...Repeated for Undervoltage 12
End of Fault Protection (Read/Write Grouped Setting) (24 Modules)
B90
6B80
End of Fault Protection 1 Function
0 to 1
---
1
F102
0 (Disabled)
"
6B81
End of Fault Protection 1 CT
0 to 23
---
1
F400
0
"
6B82
End of Fault Protection 1 Pickup
0 to 30
pu
0.001 F001
1200
"
6B83
End of Fault Protection 1 Breaker Open
0 to 4294967295
---
1
F300
0
"
6B85
End of Fault Protection 1 Breaker Delay
0 to 65.535
s
0.001 F001
400
"
6B86
End of Fault Protection 1 Manual Close
0 to 4294967295
---
1
F300
0
"
6B88
End of Fault Protection 1 Pickup Delay
0 to 65.535
s
0.001 F001
40
"
6B89
End of Fault Protection 1 Block
0 to 4294967295
---
1
F300
0
Products
Address Register name
Range
Units
Step
Format
Default
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...