POWER MONITOR ERROR CODES

During Power-Up (occurs only during power-up)

Normal Power–

L1-L2

L1-N

No message

>150VAC

>90VAC AND <150VAC

SUPPLY OPEN

L1-L2

L1-N

NEUTRAL

NA

<90VAC

SUPPLY

L1-L2

L1-N

MISWIRED

<90VAC

>90VAC AND <150VAC

L1-L2

L1-N

NA

>150VAC

SENSE 120V

L1-L2

L1-N

ENTERING

>90VAC and <150VAC

>90VAC AND <150VAC

SALES MODE

After Power-Up (can occur anytime during operation)

Normal Power–

L1-L2

L1-N

No message

NA

>90VAC AND <150VAC

SUPPLY OPEN

L1-L2

L1-N

NEUTRAL

NA

<90VAC

SUPPLY

L1-L2

L1-N

MISWIRED

NA

>150VAC

LOW POWER

L1-L2

L1-N

<150VAC

NA

Note:

Low Power supersedes Supply Open Neutral

229C4059P444-1

Cooking Mode

Elements

Convection Fan

Vent Fan

Left Cooling 

Fans

Right Cooling 

Fans

Bake

bake & broil as required

option to use in 

Preheat

ON

ON

ON

Broil

broil as required

NO

ON

ON

ON

Convection Bake Multi

convection as required

YES

ON

ON

ON

Convection Bake 1-Rack

bake & broil as required

YES

ON

ON

ON

Convection Roast

bake & broil as required

YES

ON

ON

ON

Self-Clean

bake & broil as required

Speed bake

bake, convection, broil 
and microwave as 
required

YES - as required

ON

ON

Speed broil

broil & microwave as 
required

YES - as required

ON

ON

Defrost

microwave as required

YES - as required

ON

ON

Proof (some models)

oven light

YES - as required

ON

-----

-----

Dehydrate (some models)

convection as required

YES

ON                ON

            ON

Left cooling fan turns OFF after 5 minutes if the current oven operation does not require it ON.
The vent fan turns OFF after a minimum of 7 minutes and the sensor temperature <200

°

F for 2 minutes.

The right cooling fan turns OFF after a minimum of 7 minutes and the sensor temperature <200

°

F for 2 minutes or after 

about 20 minutes, whichever comes first.

NOTE: 

For the bake, broil or convection elements or the microwave to operate, 

BOTH THE LEFT AND COOLING FANS 

MUST BE ON 

and engage the sail switches.

NO                    OFF                ON

ON

ON

ON

ON

MAIN POWER BOARD WIRING

GENERAL OPERATION—

BASICS OF ELEMENT CYCLING