background image

GE

Lumination

Installation Guide

12

Volt

6

7

8
9

1
2

3

4
5

UL approved 18 AWG (0.82 mm

2

) supply wire

UL approved 22-14 AWG (0.33-2.08 mm

2

wire connectors or 22-18 AWG 
(0.33-0.82 mm

2

) in-line/IDC connectors

#6 or #8 (M3 or M4) screws or 1/8 inch 
(3.2 mm) rivets

End caps (GETMEC1)

Tetra

®

 Power Supply (GEPS12-20, 

GEPS12-60, GEPS12-60U)

Tetra

®

 PowerStrip LED modules 

(GEWHSSP3-65K, GEWWSSP3-41K)

Components

imagination at work

Tetra

®

 

PowerStrip

LED Lighting System

6180 Halle Drive • Valley View, Ohio 44125-4635 • USA
P: 216.606.6555 • F: 216.606.6599 • www.led.com • [email protected]

Lumination, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of Lumination, LLC. The GE brand, logo, and ecomagination are trademarks of the General Electric Company. 
© 2009 Lumination, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

SIGN066-R060909

For customer service & technical support, contact:

1-888-MY-GE-LED

      (1.888.694.3533)

(GEWHSSP3-65K, GEWWSSP3-41K)

RISK OF ELECTRIC SHOCK:

• Turn power OFF before inspection, installation    

  or removal.

• Properly ground Tetra Power Supply enclosure.

RISK OF FIRE:

• Follow all NEC and local codes.

• Use only UL approved wire for input/output  

 

  connections. Minimum size 18 AWG (0.82 mm

2

)

WARNING!

Conforms to the following standards:

Prepare Electrical Wiring

Electrical Requirements

• Do not use in wet locations.
• The grounding and bonding of the LED 

Driver shall be done in accordance with 

National Electric Code (NEC) Article 600.

• Follow all National Electric Codes (NEC) and 

local codes.

Symptom

Solution

Row of modules does 

not light

• Check wire connections to power supply to ensure red stripe-to-red and white-to-black connections.

• Check row-to-row polarity connections.

Sign does not light

• Check input and output voltage and check power supply input/output connections.

• Check polarity connections.

Individual modules 

do not light

• Remove module and replace with another working module.

Modules are dim

• Ensure the overall length of the Tetra

®

 LED system does not exceed the maximum load.

• Ensure the length and gauge  of the supply wire is equal to or below the recommended remote  

 

  mounting distance.

Troubleshooting

Tetra

®

 PowerStrip Assembly Support 

(GEDSAS1) 

Tetra

® 

PowerStrip Tube Connector (GEDSTC1)

Tetra

® 

PowerStrip Assembly End Cap 

(GEDSMB1)

Tetra

® 

PowerStrip Tube (GEDSAT96)

OPTIONAL

Snap together tube halves.

Feed wire through assembly end cap and slide into 

assembly end cap.

3

4

Place Tetra PowerStrip Assembly into correct position 

and fasten assembly end cap to the sign with two 

#6 (M3) screws.

When mounting horizontally assembly supports MUST 

BE used to support tubes approximately every 4 ft. 

(1.22 m) by mounting assembly supports around tubes 

and securing into support stringers with screws.

OPTIONAL:

 Install a tube connector for longer spans 

up to 10 ft. (3.05 m) and push tube ends into connector. 

5

6

BEFORE YOU BEGIN

Read these instructions completely and carefully.

WARNING/ADVERTISEMENT

Risk of electrical shock.

 Disconnect power before 

servicing or installing product.

Risque de choc électrique. Couper l’alimentation 

avant le dépannage ou avant l’installation du produit.

10

10

1

2

3

4

5

6

7

8

9

Support stringers

Tube 

connector

Assembly 

support

Summary of Contents for Tetra PowerStrip GEWHSSP3-65K

Page 1: ...Follow all National Electric Codes NEC and local codes Symptom Solution Row of modules does not light Check wire connections to power supply to ensure red stripe to red and white to black connections Check row to row polarity connections Sign does not light Check input and output voltage and check power supply input output connections Check polarity connections Individual modules do not light Remo...

Page 2: ...wire from the power supply to inside the sign and connect to the first module on the strip 3 To power supply Red Red stripe White Black Connect the red stripe wire of the LED system to the red wire of the power supply Connect the white wire of the LED system to the black wire of the power supply 4 Power Supply To LED System Red Black NOTE Refer to the power supply installation instructions for loa...

Page 3: ...wire from the power supply to inside the sign and connect to the first module on the strip 3 To power supply Red Red stripe White Black Connect the red stripe wire of the LED system to the red wire of the power supply Connect the white wire of the LED system to the black wire of the power supply 4 Power Supply To LED System Red Black NOTE Refer to the power supply installation instructions for loa...

Page 4: ...Follow all National Electric Codes NEC and local codes Symptom Solution Row of modules does not light Check wire connections to power supply to ensure red stripe to red and white to black connections Check row to row polarity connections Sign does not light Check input and output voltage and check power supply input output connections Check polarity connections Individual modules do not light Remo...