Power Supply Features
(GEPS24D-80U)
• Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip,
Tetra Contour and Tetra Contour LS LED lighting systems
• Compatible with 0-10V Dimming controller
• Class 2 wiring per NEC Article 725
• Damp location rated
• IP66 rated: separate enclosure required
Connect the supply wire that
is attached to the Tetra LED
System to the red (+) and black (-)
output wires of the power supply
as outlined in the “
Electrical
Connections
” section of your LED
system’s
Installation Instructions.
1
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
2
)
or 18-10 AWG (0.82-5.26mm
2
)
twist-on wire connectors.
Properly ground power supply in
accordance with National Electric
Code (NEC) Article 600.
3
Tetra
®
LED Systems Power Supply
Connect the (+) purple and (-) gray
wires of the Tetra Dimming Power
Supply to the 0-10V dimming
controller. Refer to the dimming
controller installation instructions for
specific connection information.
2
GE
Lighting Solutions
Installation Guide
24
Volt
To Tetra LED System
To Dimming
controller
Output
wires
White (neutral)
Black (line)
Red (+)
Black (-)
AC line
To Tetra LED System
Purple (+)
Purple (+)
Gray (-)
Gray (-)
Dimming
controller
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE:
• Use only Tetra
®
supply wire to make connection from Tetra
®
power
supply to Tetra
®
LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82mm
2
)
• Follow all NEC and local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation
électrique Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que le fil d’approvisionnement Tetra® pour faire la
connexion entre l’alimentation Tetra
®
et la bande DEL Tetra
®
.
• N’utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82mm
2
).
• Respectez tous les codes NEC et codes locaux.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
Power Supply Installation